0313.500VXIDP
Part Number 0313.500VXIDP
Manufacturer Littelfuse Inc.
Description FUSE GLASS 500MA 250VAC 3AB 3AG
Quantity Available 6045 pcs new original in stock.
Request Stock & Quotation
Datasheets
Download 0313.500VXIDP Details PDF
0313.500VXIDP Price Request Price & Lead Time Online
or Email us: Info@ariat-tech.com
Technical Information of 0313.500VXIDP
Manufacturer Part Number 0313.500VXIDP Category Circuit Protection
Manufacturer Hamlin / Littelfuse Description FUSE GLASS 500MA 250VAC 3AB 3AG
Package / Case 3AB, 3AG, 1/4' x 1-1/4' Quantity Available 6045 pcs
Voltage Rating - AC 250 V Size / Dimension 0.250' Dia x 1.250' L (6.35mm x 31.75mm)
Series 313 Response Time Slow Blow
Package / Case 3AB, 3AG, 1/4' x 1-1/4' Package Bulk
Operating Temperature -55°C ~ 125°C Mounting Type Requires Holder
Melting I²t 2.55 Fuse Type Cartridge, Glass
DC Cold Resistance 1.26 Ohms Current Rating (Amps) 500 mA
Color - Breaking Capacity @ Rated Voltage 35A
Approval Agency CE, CSA, UL  
Download0313.500VXIDP PDF - DE.pdf
0313.500VXIDP are New and Original in Stock, Find 0313.500VXIDP electronics components stock, Datasheet, Inventory and Price at Ariat-Tech.com Online, Order 0313.500VXIDP Littelfuse Inc. with warrantied and confidence from Ariat Technology Limitd. Ship via DHL/FedEx/UPS. Payment with Wire Transfer or PayPal is OK.
Email us: Info@Ariat-Tech.com or RFQ 0313.500VXIDP Online.

Frequently Asked Questions

  • What is the thermal response characteristic of the Littelfuse 0313.500VXIDP fuse, and how does its slow-blow rating affect circuit protection in switching power supplies? The 0313.500VXIDP is rated as a slow-blow (time-delay) fuse, meaning it tolerates brief inrush currents without nuisance operation while still responding to sustained overcurrent faults. In switching power supplies, where input rectifier stages commonly exhibit transient inrush currents of 2–5× the steady-state value during soft-start or initial charging of bulk capacitors, the slow-blow characteristic prevents false trips. The 0313.500VXIDP's melting I²t value of 2.55 provides predictable thermal response—current overloads of 150–200% of the 500 mA rating may require several seconds to trigger, while sustained faults at 300%+ ratings clear within milliseconds. This time-energy relationship makes the 0313.500VXIDP suitable for protecting AC-powered circuits where momentary transients are expected during normal operation.
  • How does the 250 VAC rating of the 0313.500VXIDP apply to DC circuit protection, and what voltage derating should be considered for direct DC applications? The 0313.500VXIDP carries a 250 VAC rating as its primary specification; however, its DC rating is not independently specified in the datasheet, which is common practice for fuses certified under AC standards. The DC cold resistance of 1.26 Ohms indicates low arc-sustaining voltage. In practice, DC fuses typically operate at reduced breaking capacity compared to their AC ratings due to the absence of line-frequency current zero-crossings that aid arc extinction in AC circuits. For DC applications, particularly at high DC voltages (100+ VDC), the 0313.500VXIDP should be operated at or below 125 V DC to ensure reliable arc quenching. At higher DC levels, a fuse with an explicit high-voltage DC rating or higher breaking capacity specification should be substituted. The 0313.500VXIDP is most reliably applied in AC mains circuits or low-voltage DC rails where arc extinction is less problematic.
  • What circuit topologies and load types are compatible with the 0313.500VXIDP's 35 A breaking capacity at rated voltage? The 0313.500VXIDP specifies a breaking capacity of 35 A at its 250 V rated voltage. This breaking capacity defines the maximum fault current the fuse can safely interrupt without rupturing its cartridge or creating uncontrolled arcing. For AC mains protection (250 VAC, 50/60 Hz), a 35 A breaking capacity is typical for residential and light commercial applications where available short-circuit fault currents are typically 5–20 kA on branch circuits but limited by upstream distribution protection. The 0313.500VXIDP is therefore suitable for protecting individual appliance power supplies, heating elements, or motor soft-starter circuits with moderate fault levels. However, in industrial three-phase systems or close to main switchboards where fault currents may exceed 35 kA, the 0313.500VXIDP would be undersized and could fail catastrophically if subjected to such faults. Circuit designers must verify that the prospective short-circuit current at the point where the 0313.500VXIDP is installed does not exceed its 35 A breaking capacity.
  • How does the DC cold resistance specification of 1.26 Ohms in the 0313.500VXIDP affect power dissipation and thermal stability in continuous-operation scenarios? The 0313.500VXIDP exhibits a DC cold resistance of 1.26 Ohms when unheated. At the fuse's rated current of 500 mA (0.5 A), steady-state I²R power dissipation equals (0.5)² × 1.26 = 0.315 W. This dissipation is modest and typically absorbed by the holder and surrounding air without raising fuse temperature significantly above ambient. However, resistance increases with temperature as the metal element heats; at elevated operating temperatures or near thermal limits, actual resistance may be 10–20% higher than the cold value. The 0313.500VXIDP's operating temperature range of −55°C to 125°C means its internal element is designed to tolerate 125°C when subjected to external thermal stress. At 500 mA continuous current in a poorly ventilated holder, the combination of self-heating plus external thermal load may approach this limit, potentially reducing the fuse's margin to melt-point and increasing sensitivity to ambient temperature fluctuations. For thermally constrained applications, designers should verify that continuous operating current remains below 70–80% of the 500 mA rating to maintain stable margin.
  • What are the practical differences between the 0313.500VXIDP and its substitutes listed as 0313.500MXP or 0313.500HXIDP, and when would alternative substitutes be necessary? The 0313.500VXIDP's substitute list includes 0313.500MXP (medium-blow), 0313.500HXIDP (high-breaking-capacity variant), and 0313.500H. The primary distinction lies in response characteristics and breaking capacity. The 0313.500MXP uses a medium-blow element optimized for circuits with moderate inrush tolerance, responding faster than the 0313.500VXIDP to sustained faults but slower than fast-blow alternatives. The 0313.500HXIDP variant maintains the slow-blow characteristic but offers higher breaking capacity, suitable for industrial installations with elevated fault currents. When the 0313.500VXIDP's 35 A breaking capacity proves marginal or when measured prospective fault currents approach 30–35 A, substituting the 0313.500HXIDP provides design safety margin. Conversely, if circuit topology or application experience indicates faster fault response is beneficial (e.g., protecting sensitive semiconductor loads), the 0313.500MXP presents a viable swap. The 3SB 500 listed as a substitute represents a competing manufacturer's equivalent; compatibility depends on holder type acceptance and certification body approval. Designers should confirm that any substitute maintains the same physical dimensions (0.250" Dia × 1.250" L, 3AB/3AG holder), voltage rating, and approval markings (CE, CSA, UL) to avoid unintended changes in circuit protection reliability.
  • How do the CE, CSA, and UL approval markings on the 0313.500VXIDP affect design compliance for equipment sold in different geographic markets? The 0313.500VXIDP carries three independent approval certifications: CE (European conformity), CSA (Canadian Standards Association), and UL (Underwriters Laboratories, North America). For equipment destined for European markets, the CE marking confirms compliance with the Low Voltage Directive (LVD) and relevant harmonized standards for fuse performance, breaking behavior, and thermal ratings. North American markets require UL certification; equipment using an unapproved fuse may fail regulatory acceptance or liability review. Canadian equipment must meet CSA requirements, which closely align with UL but maintain independent testing protocols. Designers targeting multi-market distribution benefit from the 0313.500VXIDP's triple certification because a single BOM component satisfies protection requirements across EU, USA, and Canada without substitution. However, if regulatory documentation or compliance reports are needed for product certification, each market's approval body may require specific technical file references—designers should confirm that the manufacturer's technical documentation explicitly references the relevant certification (e.g., UL file number) to support regulatory submissions.
  • What design considerations are necessary when integrating the 0313.500VXIDP into a 250 VAC mains-input circuit with a rectifier bridge and bulk capacitor, and how does the melting I²t value inform design decisions? Mains-powered circuits using the 0313.500VXIDP must account for two distinct overcurrent scenarios: (1) normal inrush during initial capacitor charging, and (2) sustained faults from component failure. During cold-start, a rectified 250 VAC source charging a typical bulk capacitor (100–470 µF) generates inrush current that may reach 3–5 A for 10–50 ms depending on rectifier source resistance and transformer impedance. The 0313.500VXIDP's slow-blow melting I²t of 2.55 is engineered to withstand this transient without opening. At 3 A inrush, the energy integral I²t = (3)² × 0.020 = 0.18 seconds-squared, well below the fuse's 2.55 threshold. However, if a rectifier diode fails short or a capacitor develops leakage, sustained current of 1–2 A beyond the initial charge cycle will accumulate thermal energy and eventually trip the fuse within seconds. Designers should therefore specify a soft-start circuit or inrush-limiting thermistor if the actual inrush peak is forecast to exceed 2 A continuously or 3 A for periods beyond 100 ms—this improves reliability margin and reduces nuisance fuse replacement. The 0313.500VXIDP's melting I²t of 2.55 provides a quantitative design anchor: if measured or simulated inrush produces I²t > 2.0, the fuse becomes marginal; values > 2.5 risk nuisance operation.
  • How does the 0313.500VXIDP's ROHS3 compliance and REACH Unaffected status affect long-term component availability and environmental qualification for medical or aerospace applications? The 0313.500VXIDP is marked ROHS3 Compliant, indicating it contains no lead solder, cadmium, mercury, hexavalent chromium, PBB, or PBDE—standards enforced in EU markets since 2006. REACH Unaffected status means the component is exempt from REACH chemical registration requirements, typically because Littelfuse's manufacturing process does not introduce substances of very high concern (SVHC) above reporting thresholds. For commercial applications sold in Europe or by EU-certified integrators, ROHS3 compliance is mandatory; the 0313.500VXIDP satisfies this requirement out-of-box. For medical device applications subject to biocompatibility and material traceability review, the ROHS3 designation provides evidence of restricted substance control. However, medical or aerospace programs often impose stricter material qualification—such as lead-free solder compatibility, thermal cycling endurance, or historical supplier audits—that ROHS3 compliance alone does not guarantee. Designers in these regulated sectors should confirm with Littelfuse that the 0313.500VXIDP meets any additional qualification matrix (e.g., IPC-A-610, AS9100, ISO 13485) before incorporating it into design-locked BOMs. The broad availability of ROHS3-compliant alternatives ensures that the 0313.500VXIDP is unlikely to become obsolete due to environmental legislation within its design lifetime.
  • What mounting and holder considerations are critical when designing a circuit board layout for the 0313.500VXIDP to ensure reliable contact and compliance with electrical safety spacing rules? The 0313.500VXIDP is a cartridge fuse requiring a separate holder—it cannot be soldered or directly mounted to PCB pads. Standard 3AG/3AB holders accept the 0313.500VXIDP's 0.250" diameter, 1.250" length form factor and provide spring-loaded contact clips. Electrical safety standards (IEC 60950, UL 60950) typically mandate 6–12 mm minimum spacing between the fuse holder's live terminals and any adjacent conductors, mounting hardware, or human-accessible surfaces. PCB layout must therefore reserve space around the fuse holder to prevent accidental contact during maintenance or probe access. The holder itself dissipates fuse self-heating via the metal spring clips and body; mounting orientation (horizontal vs. vertical) affects airflow—horizontal orientation in an open-air assembly typically provides better cooling than vertical orientation in a confined enclosure. The 0313.500VXIDP's 1.26 Ohm cold resistance means contact resistance in the holder contributes to total circuit resistance; corroded or loose holder contacts can introduce 0.1–0.5 Ohm additional resistance, degrading performance margin and increasing local heating. During assembly, designers should specify contact cleaning or gold-plated holder contacts to minimize degradation. The fuse holder assembly must be rated for the same 250 VAC voltage and 35 A breaking capacity as the 0313.500VXIDP; mismatched holders may not provide adequate arc containment during fault clearing.
  • How does the 0313.500VXIDP's operating temperature range of −55°C to 125°C affect its application in industrial outdoor enclosures or automotive underhood environments? The 0313.500VXIDP is rated for continuous operation between −55°C and 125°C. In outdoor industrial enclosures without active cooling, internal air temperatures may approach 70–80°C in summer operation; the 45°C margin to the 125°C limit provides reasonable safety for fuse element stability. Automotive underhood environments, particularly near engine bay components, routinely reach 100–120°C locally. The 0313.500VXIDP can tolerate these conditions without degradation, but designers must account for the fact that fuse trip point shifts downward at elevated temperature—the fuse's melting current effectively decreases as the element approaches its maximum temperature. A circuit that operates at 90% of the 500 mA rating at 20°C ambient will experience higher margin erosion at 100°C ambient due to reduced thermal headroom between steady-state temperature and melt-point. For underhood automotive applications, conservative design practice calls for limiting nominal operating current to 70–80% of the 0313.500VXIDP's 500 mA rating (i.e., 350–400 mA maximum) to maintain protection margin across the full temperature range. Conversely, at −55°C (arctic or high-altitude operation), the fuse's element becomes more brittle; mechanical shock during vehicle operation could initiate cracking. The 0313.500VXIDP's Moisture Sensitivity Level (MSL) rating of 1 (Unlimited) indicates the glass cartridge and internal element are not sensitive to humidity and do not require special storage or handling, supporting reliability in fluctuating outdoor environments.
  • Can the 0313.500VXIDP be used for DC circuit protection on a 48 V or 120 V DC rail in industrial control systems, and what additional measures are necessary to ensure reliable operation? The 0313.500VXIDP is rated 250 VAC with an unspecified DC rating. While its 35 A breaking capacity and 1.26 Ohm cold resistance suggest it could physically interrupt DC currents, fuse performance in DC circuits diverges significantly from AC performance because DC faults lack the natural current zero-crossing that aids arc extinction in AC systems. At 48 VDC, the 0313.500VXIDP would likely function acceptably for low-fault-current applications (< 10 A fault); the arc voltage drop across the clearing fuse element may be sufficient to de-energize the circuit. However, at 120 VDC with higher prospective fault currents (20+ A), the 0313.500VXIDP could experience arc reignition or incomplete clearing, potentially damaging the fuse cartridge or overheating the holder. Industrial control systems using 48 V or 120 V DC should employ fuses with explicit DC certification and measured DC breaking capacity (e.g., Littelfuse 0313.500HDC or equivalent), not AC-rated variants. If the 0313.500VXIDP must be used in a low-voltage DC application due to supply constraints, it should be operated at reduced current ratings (< 300 mA nominal) to minimize fault energy and arc intensity. Alternatively, complementary protection using a DC contactor or semiconductor crowbar circuit can manage fault clearing, allowing the 0313.500VXIDP to serve as a secondary thermal cutout rather than the primary fault-interrupt device.
  • What is the significance of the 0313.500VXIDP's melting I²t value of 2.55 in the context of semiconductor load protection, and does slow-blow response provide adequate margin for transient suppression in switched-mode circuits? The 0313.500VXIDP's melting I²t of 2.55 defines the thermal energy threshold required to melt the fuse element. Semiconductor devices such as MOSFETs, bridge rectifiers, or thyristors tolerate short transient current spikes (100–500 µs duration) but fail catastrophically if exposed to sustained overcurrent lasting milliseconds. The slow-blow 0313.500VXIDP is designed to allow transients without melting; however, if a semiconductor junction shorts or a gate-drive circuit malfunctions, sustained current at 1–2× the rated 500 mA will accumulate energy. At 1 A sustained current, the I²t accumulation equals (1)² × t = t seconds-squared; reaching 2.55 requires approximately 2.55 seconds. This response time is beneficial for circuits with expected inrush but problematic for protecting high-frequency switch-mode supplies where a failed MOSFET can inject 5–10 A into the rail within microseconds. The semiconductor damage occurs long before the slow-blow fuse reaches its melting I²t. For switch-mode circuits, auxiliary fast-blow fuses or active electronic current-limiting circuits (eFuse controllers) should protect semiconductor elements, with the 0313.500VXIDP serving as a secondary input-stage protection. The 0313.500VXIDP's slow-blow characteristic is therefore well-suited to mains input protection (tolerating capacitor inrush) but inadequate as the sole protection for sensitive load-side semiconductors requiring sub-millisecond response.
  • How does the 0313.500VXIDP compare to modern electronic fuses or PTC thermistors in terms of reset behavior and maintenance cycles, and what are the trade-offs? The 0313.500VXIDP is a one-time-use fuse; once the element melts during an overcurrent event, it must be manually replaced—no automatic reset occurs. This contrasts with electronic fuses (eFuses) based on semiconductor current limiters or PTC (positive temperature coefficient) thermistors that automatically recover once fault current clears. PTC thermistors exhibit reversible high-resistance behavior when overheated, returning to normal conductivity as temperature drops; they tolerate repeated fault cycles without replacement. Electronic eFuse controllers actively monitor current and switch off the gate drive to an internal MOSFET when fault thresholds are exceeded, providing precision and logging capability. The 0313.500VXIDP's advantage is simplicity, cost, and passive operation—no power supply, gate drive, or firmware required. The trade-off is that each fault event requires technician intervention and a replacement part ($0.10–$0.30 per unit), making the 0313.500VXIDP impractical for circuits experiencing frequent transient faults or in field-deployable equipment where immediate replacement is infeasible. For mains-input protection in consumer appliances or building lighting, where faults are rare and replacement cost is absorbed in service calls, the 0313.500VXIDP remains economical and reliable. For automotive or industrial applications experiencing cyclic overcurrent stress from normal operation (e.g., motor soft-start inrush), PTC thermistors or eFuse controllers reduce lifetime maintenance cost despite higher per-unit component cost.
  • What testing or validation procedures should be performed on circuits using the 0313.500VXIDP to verify protection adequacy before production release? Circuit protection validation using the 0313.500VXIDP requires empirical verification that: (1) normal inrush current does not cause nuisance fuse operation, and (2) actual fault conditions trigger reliable fuse clearing. Designers should conduct the following tests before production release: (1) Cold-start inrush measurement—connect the 0313.500VXIDP-protected circuit to mains using a current probe or series ammeter, measure peak and duration of inrush current during capacitor charging, and confirm that measured I²t remains below 80% of the fuse's 2.55 melting threshold (i.e., I²t < 2.0); (2) Fault injection testing—deliberately short the load or insert a fixed resistive load to generate 150–200% rated current and measure clearing time using an oscilloscope, confirming the 0313.500VXIDP opens within 5–10 seconds; (3) High-temperature operation—repeat inrush and fault tests at 80°C and 120°C ambient or with external heating applied, confirming no premature fuse operation or excessively delayed response; (4) Thermal cycling—expose assembled boards with the 0313.500VXIDP to −20°C to +80°C cycles (10 cycles minimum) and retest inrush to confirm contact resistance stability. Documentation should record measured I²t values, fault-clearing times, and ambient temperatures to establish a design margin matrix. This validation ensures that production units behave predictably and that field failures due to protection inadequacy are minimized.
  • Is the 0313.500VXIDP suitable for three-phase industrial motor protection, or should a three-phase fuse cartridge or coordinated fuse set be specified instead? The 0313.500VXIDP is a single-phase cartridge fuse designed for protecting individual circuits at 250 VAC, 50/60 Hz. Three-phase industrial motors require protection of all three phase conductors; if only a single phase is protected using the 0313.500VXIDP, an unbalanced fault or single-phase failure could damage motor windings before any overcurrent detection occurs. Three-phase motor protection demands either (1) a coordinated set of three identical fuses (three 0313.500VXIDP cartridges in a common three-pole base), or (2) a dedicated three-phase fuse cartridge assembly rated for three-phase current distribution. Additionally, motor inrush current during soft-start or direct-on-line (DOL) starting can reach 3–7× the motor's full-load current for several seconds; the 0313.500VXIDP's slow-blow response is beneficial here, but the designer must confirm that the inrush I²t for all three phases combined remains within protective limits. Industrial motor protection also typically incorporates thermal overload relays that monitor temperature rise independent of fuse response, providing coordinated protection against both short-circuit (fuse role) and sustained overload (thermal relay role). For small fractional-horsepower motors, using three individual 0313.500VXIDP cartridges in a three-pole holder offers a cost-effective approach if verified against the motor's actual inrush profile and fault current rating. For larger motors or critical applications, consulting motor protection coordination software and working with a protection engineer is recommended to ensure the 0313.500VXIDP (or larger equivalent) is correctly sized and coordinated with upstream system protection.
  • *Part No. Manufacturer Target Price(USD) *Request Qty Action
    Add Item

    Enter Your Contact Information

    Submit
    0313.500VXIDP Stock0313.500VXIDP Price0313.500VXIDP Electronics
    0313.500VXIDP Components0313.500VXIDP Inventory0313.500VXIDP Digikey
    Supplier 0313.500VXIDPOrder 0313.500VXIDP Online Inquiry 0313.500VXIDP
    0313.500VXIDP Image0313.500VXIDP Picture0313.500VXIDP PDF
    0313.500VXIDP DatasheetDownload 0313.500VXIDP DatasheetManufacturer Hamlin / Littelfuse
    Related parts for 0313.500VXIDP
    Image Part Number Description Manufacturer PDF Get a Quote
    0313.500HXP FUSE GLASS 500MA 250VAC 3AB 3AG Littelfuse Inc.
    Get a Quote
    0313.500HXID FUSE GLASS 500MA 250VAC 3AB 3AG Littelfuse Inc.
    Get a Quote
    0313.600HXP FUSE GLASS 600MA 250VAC 3AB 3AG Littelfuse Inc.
    Get a Quote
    0313.600H FUSE GLASS 600MA 250VAC 3AB 3AG Littelfuse Inc.
    Get a Quote
    0313.700HXP FUSE GLASS 700MA 250VAC 3AB 3AG Littelfuse Inc.
    Get a Quote
    0313.500MXP FUSE GLASS 500MA 250VAC 3AB 3AG Littelfuse Inc.
    Get a Quote
    0313.600VXP FUSE GLASS 600MA 250VAC 3AB 3AG Littelfuse Inc.  
    Get a Quote
    0313.600MXP FUSE GLASS 600MA 250VAC 3AB 3AG Littelfuse Inc.
    Get a Quote
    0313.700H FUSE GLASS 700MA 250VAC 3AB 3AG Littelfuse Inc.
    Get a Quote
    0313.500VXP FUSE GLASS 500MA 250VAC 3AB 3AG Littelfuse Inc.
    Get a Quote
    0313.700VXP FUSE GLASS 700MA 250VAC 3AB 3AG Littelfuse Inc.  
    Get a Quote
    0313.400HXP FUSE GLASS 400MA 250VAC 3AB 3AG Littelfuse Inc.
    Get a Quote
    0313.700MXP FUSE GLASS 700MA 250VAC 3AB 3AG Littelfuse Inc.
    Get a Quote
    0313.400MXP FUSE GLASS 400MA 250VAC 3AB 3AG Littelfuse Inc.
    Get a Quote
    0313.500H FUSE GLASS 500MA 250VAC 3AB 3AG Littelfuse Inc.
    Get a Quote
    0313.750H FUSE GLASS 750MA 250VAC 3AB 3AG Littelfuse Inc.
    Get a Quote
    0313.500HXIDP FUSE GLASS 500MA 250VAC 3AB 3AG Littelfuse Inc.
    Get a Quote
    0313.375VXP FUSE GLASS 375MA 250VAC 3AB 3AG Littelfuse Inc.  
    Get a Quote
    0313.400H FUSE GLASS 400MA 250VAC 3AB 3AG Littelfuse Inc.
    Get a Quote
    0313.400VXP FUSE GLASS 400MA 250VAC 3AB 3AG Littelfuse Inc.  
    Get a Quote

    News

    More
    Google is in talks with Marvell to develop two AI inference...

    On April 19, 2026 (local time), media reports citing sources familiar with the matter revealed that Google, a subsidiary of Alphabet, is in talks with...

    TSMC Advances Panel-Level Packaging Technology; CoPoS Pilot...

    According to *The Business Times*, TSMC’s CoPoS (Chip-on-Panel-on-Substrate) pilot production line began delivering equipment to its R&D team in Febr...

    Anthropic Partners with Google and Broadcom to Deploy Sever...

    On April 6 local time, U.S. artificial intelligence (AI) technology giant Anthropic announced that it has signed a new agreement with Google and Broad...

    Microsoft Announces $5.5 Billion Investment to Expand Cloud...

    On April 1, Microsoft announced it would invest $5.5 billion in Singapore to continue expanding its cloud and artificial intelligence (AI) infrastruct...

    Samsung has reached an exclusive HBM4 supply agreement with...

    Samsung Electronics will be the first to exclusively supply its next-generation HBM4 to OpenAI, the world’s largest artificial intelligence (AI) comp...

    New Products

    More
    Texas Instruments TPS92542-Q1 Synchronous Boost Controller

    Texas Instruments TPS92542-Q1 Synchronous Boost Controller contains a synchronous boost controller and a two-channel monolithic synchronous buck LED d...

    Toshiba TB67H453 Single Channel H-Bridge Driver

    Toshiba TB67H453 Single Channel H-Bridge Driver has a current monitoring function with voltage feedback from the ISENSE output pin. The device's absol...

    STMicroelectronics STSAFE-A120 Authentication ICs

    STMicroelectronics STSAFE-A120 Authentication ICs are highly secure integrated circuits designed to protect sensitive data and devices through advance...

    STMicroelectronics STSAFE-A Optimized Authentication ICs

    STMicroelectronics STSAFE-A Optimized Authentication ICs leverage advanced cryptographic algorithms and key management techniques to protect sensitive...

    Diodes Incorporated PI3DPX1235Q 64 Crossbar Linear ReDriver

    Diodes Incorporated PI3DPX1235Q 6:4 Crossbar Linear ReDriver supports DP link-training transparent for source-side applications. The PI3DPX1235Q compl...

    Email: Info@ariat-tech.comHK TEL: +852 30501966ADD: Rm 2703 27F Ho King Comm Center 2-16,
    Fa Yuen St MongKok Kowloon, Hong Kong.