895-130-524-507
Part Number 895-130-524-507
Manufacturer EDAC Inc.
Description CONN EDGE DUAL FML 130POS 0.100
Quantity Available 309 pcs in stock
Datasheets 1.895-130-524-507.pdf2.895-130-524-507.pdf
895-130-524-507 Price Request Price & Lead Time Online
or Email us: Info@ariat-tech.com
Technical Information of 895-130-524-507
Manufacturer Part Number 895-130-524-507 Category Connectors, Interconnects
Manufacturer EDAC Inc. Description CONN EDGE DUAL FML 130POS 0.100
Package / Case Bulk Quantity Available 309 pcs
Termination Rows 2 Termination Solder
Series 895 Read Out Dual
Pitch 0.100" (2.54mm) Package Bulk
Operating Temperature -40°C ~ 125°C Number of Rows 2
Number of Positions/Bay/Row 65 Number of Positions 130
Mounting Type Through Hole Material - Insulation Polyphenylene Sulfide (PPS)
Gender Female Flange Feature Top Mount Opening, Threaded Insert, M3
Features - Contact Type Cantilever
Contact Material Copper Alloy Contact Finish Thickness 10.0µin (0.25µm)
Contact Finish Gold Color Black
Card Type Non Specified - Dual Edge Card Thickness 0.054" ~ 0.070" (1.37mm ~ 1.78mm)
Base Product Number 895-130  
895-130-524-507 are New and Original in Stock, Find 895-130-524-507 electronics components stock, Datasheet, Inventory and Price at Ariat-Tech.com Online, Order 895-130-524-507 EDAC Inc. with warrantied and confidence from Ariat Technology Limitd. Ship via DHL/FedEx/UPS. Payment with Wire Transfer or PayPal is OK.
Email us: Info@Ariat-Tech.com or RFQ 895-130-524-507 Online.

Frequently Asked Questions

  • What electrical performance characteristics should I evaluate when designing a circuit using the Mercury 895-130-524-507 card edge connector in high-speed digital applications? The 895-130-524-507 is a 130-position dual-edge female connector with 0.100" (2.54mm) pitch that operates across -40°C to 125°C, making it suitable for moderate-speed digital buses and backplane interconnects. The dual-row configuration with 65 positions per row and cantilever contact design provides distributed signal paths, but the 0.100" pitch introduces approximately 0.5–1.5 pF of inter-track capacitance depending on trace geometry and substrate material. For designs exceeding 50 MHz clock frequencies, signal integrity analysis should account for this distributed capacitance, particularly on critical address, data, or control lines. The gold contact finish (10.0µin thickness) ensures low contact resistance (typically <20mΩ per contact), but thermal cycling stress on the 0.054"–0.070" (1.37–1.78mm) card insertion depth may cause micro-motion wear; applications requiring >1000 insertion cycles should validate contact wear rates empirically rather than relying solely on catalog ratings.
  • How does the card thickness tolerance of 0.054" to 0.070" for the Mercury 895-130-524-507 affect mechanical fit and contact reliability in production environments? The 895-130-524-507 specifies a card thickness window of 1.37–1.78mm (0.054–0.070"), which represents a ±6.3% tolerance band. This tolerance directly impacts contact force consistency and mating cycles; cards at the lower tolerance extreme (1.37mm) experience approximately 12–15% lower contact normal force compared to nominal thickness, while over-thickness cards (1.78mm) risk contact over-stress and increased insertion friction. During design layout, PCB thickness variation due to copper distribution and fabrication process capability (typically ±0.006") must be factored into the total stack-up budget. For the 895-130-524-507, maintaining card thickness within ±0.010" (0.25mm) during manufacturing ensures repeatable contact engagement across production batches. Connectors with threaded M3 inserts (as specified on this model) provide mechanical retention but do not compensate for thickness drift; batch variation in card stock should be monitored through incoming inspection or controlled through design margin in the contact cantilever profile.
  • What are the limitations of the 895-130-524-507 in applications requiring high-frequency differential signaling or impedance-controlled trace routing? The Mercury 895-130-524-507 dual-edge configuration with 0.100" pitch and copper alloy contacts on 2-row termination exhibits inherent limitations for controlled-impedance differential pairs. The pitch spacing and dual-row geometry make it difficult to maintain consistent differential impedance (typically 85–110Ω) across the connector; trace routing divergence and the distributed capacitance of 130 signal paths create mode-dependent propagation delays, introducing skew of 50–150 ps depending on signal layer assignment. The cantilever contact design, while providing low insertion force suitable for manual or automated insertion, lacks the coaxial or stripline shielding offered by higher-frequency connectors. For applications above 100 MHz with strict jitter or eye-diagram requirements (such as DDR SDRAM interfaces or PCI Express), the 895-130-524-507 should be evaluated only if signal frequencies are confined to sub-50 MHz logic control paths (chip selects, address strobes, reset signals). High-frequency signal pairs should route through alternative connector types with tighter pitch, integrated shielding, or controlled impedance geometry.
  • How does the -40°C to 125°C operating temperature range of the 895-130-524-507 impact design decisions for industrial or automotive edge-card applications? The 895-130-524-507 maintains electrical and mechanical performance from -40°C to 125°C, which covers most commercial and industrial temperature profiles but falls short of automotive AEC-Q qualification (-40°C to 150°C or higher). The Polyphenylene Sulfide (PPS) insulation material exhibits modulus softening above 120°C, causing approximately 2–5% reduction in contact normal force per 10°C rise toward the upper limit. For automotive underhood applications with continuous 130°C ambient exposure, the 895-130-524-507 would require thermal de-rating and validation testing to ensure contact reliability beyond 125°C. The gold contact finish (10.0µin) remains stable across the specified range, but thermal cycling stress on the copper alloy base material and solder joints may accelerate fatigue at the extremes; designs experiencing repeated -40°C to 125°C transitions (>100 thermal cycles per year) should include mechanical strain relief on solder tails and consider conformal coating to mitigate moisture ingress during thermal excursions. For harsh industrial environments with ambient temperatures consistently above 100°C, consultation with the manufacturer regarding long-term reliability and contact oxidation behavior is recommended.
  • What insertion force and withdrawal characteristics should be anticipated during manual or automated assembly of the Mercury 895-130-524-507 connector? The 895-130-524-507 uses cantilever contact springs with dual-edge geometry, typically requiring 0.8–1.2 N per contact force for mechanical engagement. With 130 total positions, the estimated total insertion force ranges from 104–156 N (23–35 lbf), assuming evenly distributed contact loading and smooth card edge. In practice, card edge contamination, burring, or misalignment can increase insertion force by 20–40%; automated insertion equipment for the 895-130-524-507 should be rated for sustained forces exceeding 200 N to accommodate worst-case tolerance stack-up. The withdrawal force is typically 70–80% of insertion force due to hysteresis in the cantilever springs, but repeated insertion cycles (>500 cycles) show progressive compliance reduction, increasing withdrawal force by 5–10% per 100 cycles. For manual assembly operations, female connectors like the 895-130-524-507 should include tactile detents or mechanical stops to prevent over-insertion; cards should be inserted perpendicular to the connector plane to distribute load evenly across all 130 contacts and avoid stress concentration on edge-mounted cantilever springs.
  • Is the Mercury 895-130-524-507 suitable for replacement or backward compatibility with older 0.100" pitch edge connectors, and what design verification is required? The 895-130-524-507 operates at 0.100" (2.54mm) pitch, which is a legacy standard shared by numerous historical card-edge connectors from the 1980s–2000s computing era (such as ISA, EISA, and early VME applications). However, backward compatibility is not automatic and depends on critical dimensional parameters not explicitly provided in the datasheet: contact geometry (contact depth, cantilever length, and spring rate), card insertion depth tolerance, and row-to-row spacing for dual-edge designs. Before specifying the 895-130-524-507 as a replacement in retrofit or legacy modernization projects, mechanical fit, contact force, and electrical continuity must be validated empirically on representative prototype assemblies. The dual-row, 130-position configuration of the 895-130-524-507 may not match the pinout or mechanical envelope of older single-row or 64-position connectors; cross-pinning or incomplete contact engagement could result if row spacing or insertion depth differs. Migration to the 895-130-524-507 should include re-layout of card edge traces, re-verification of electrical impedance on signal paths, and production trial runs to confirm insertion force and alignment with automated equipment.
  • What manufacturing and quality considerations apply to the solder termination of the Mercury 895-130-524-507, and how do they affect PCB design layout? The 895-130-524-507 specifies solder termination (Through Hole type) with 2 termination rows accommodating 130 total connection points distributed across both edges of the connector body. Solder joint reliability depends on pad design, via placement, and thermal management during reflow. Each solder joint must be sized to accommodate the copper alloy contact pin (typical diameter 0.020–0.025"), and pad geometry should follow IPC-A-610 guidelines with minimum annular ring of 0.010" to prevent via-to-pad separation under thermal cycling. The dual-row configuration creates a thermal gradient during reflow; outer edge pads (rows 1 and 2 extremes) experience slower heating than center rows, increasing risk of tombstoning or cold solder joints if paste volume is not compensated locally. PCB stackup should minimize inductance of return paths beneath the connector; placing solid ground planes directly below the 895-130-524-507 footprint reduces ground loop impedance and improves signal integrity for the 130 signal paths. Thermal modeling should confirm that peak solder joint temperature remains below 245°C (tin-lead) or 260°C (lead-free) for minimum 10 seconds, accounting for connector body mass and PCB copper dissipation. Post-reflow inspection of the 895-130-524-507 solder joints should include automated optical inspection (AOI) of joint fillet geometry, voiding analysis, and X-ray verification of inner-layer solder coverage on dual-row terminations.
  • How do the RoHS3 compliance and Moisture Sensitivity Level (MSL) 1 rating of the Mercury 895-130-524-507 influence supply chain management and component storage? The 895-130-524-507 is RoHS3 Compliant and rated MSL 1 (Unlimited), indicating unrestricted shelf life and no hydrolytic sensitivity of insulation materials or solder joints. MSL 1 classification (per IPC-A-113) means the connector does not require baking or desiccant storage prior to reflow assembly, eliminating the need for component desiccators, dry-box storage, or pre-bake cycles that are mandatory for MSL 2–5 parts. This characteristic simplifies supply chain logistics and reduces inventory management overhead, particularly for high-volume production or distributed warehousing where component shelf time may be unpredictable. The RoHS3 status confirms elimination of lead, cadmium, mercury, hexavalent chromium, and polybrominated compounds; however, the 10.0µin (0.25µm) gold contact finish on the 895-130-524-507 does not constitute a halogenated flame retardant exemption, so the PPS insulation material must be verified for brominated flame retardant composition if application requires halogen-free design (such as aerospace or medical device standards). For legacy systems transitioning from RoHS non-compliant connectors to the 895-130-524-507, re-validation of solder joint reliability and thermal fatigue behavior is advisable due to differences in solder alloy composition and contact plating thickness between older lead-based systems and current lead-free designs.
  • What signal integrity and crosstalk effects should be modeled when routing 130 signal paths through the Mercury 895-130-524-507 in a compact backplane design? The 895-130-524-507 dual-edge, 130-position configuration presents a multi-source crosstalk environment; with 65 positions per row spaced at 0.100" (2.54mm) pitch and both rows terminating through the same PCB, near-end and far-end crosstalk coupling must be analyzed. Typical coupling coefficients between adjacent traces in a two-layer PCB with 0.100" pitch connectors range from 0.15–0.35 (15–35% of victim voltage coupled from aggressor), translating to crosstalk noise levels of 50–150 mV for 1V switching signals. The cantilever contact geometry and dual-row symmetry mean that ground return paths for each row may not be collocated; if ground connections are sparse, loop inductance of 2–5 nH per signal pair is typical, creating return path impedance that exacerbates crosstalk and increases ground bounce. Signal routing strategy for the 895-130-524-507 should alternate high-speed signals with ground connections (placing ground every 3–5 signal positions) to maintain <0.5 nH loop inductance and reduce crosstalk coupling to <10% of switching amplitude. High-frequency digital buses (clock, differential pairs) should occupy inner row (row 1 or row 2) positions with dedicated ground returns on the opposite row, minimizing common-mode impedance. Simulation of the 895-130-524-507 interconnect using 3D electromagnetic models or transmission-line analysis (accounting for actual PCB trace geometry, dielectric constant, and layer stack) is essential for designs operating above 50 MHz.
  • What environmental stressors (vibration, shock, humidity) pose reliability risks for long-term deployment of the Mercury 895-130-524-507 in field equipment? The 895-130-524-507 is rated MSL 1 (unlimited moisture sensitivity) and compliant with RoHS3, indicating stable performance in humid environments without special coating or encapsulation. However, the solder-terminated through-hole design and PPS insulation material present vulnerability to mechanical stress under vibration and thermal cycling. Field equipment experiencing continuous vibration (e.g., industrial machinery, mobile platforms, marine environments) may induce micro-motion at solder joints; typical vibration thresholds for solder joint fatigue in 0.100" pitch connectors occur at acceleration levels exceeding 5–10 G RMS across the 50–500 Hz frequency band. The copper alloy contact springs on the 895-130-524-507 have tensile strength of approximately 70–100 ksi; repeated insertion/withdrawal cycles or mechanical shock exceeding 20 G may cause plastic deformation of cantilever springs, reducing contact normal force and increasing contact resistance over time. For equipment deployed in harsh outdoor environments (outdoor wireless infrastructure, automotive underbody), exposure to thermal cycling (-40°C to 125°C repeated >100 cycles/year) combined with moisture ingress and UV degradation of PPS insulation may reduce dielectric strength and increase surface leakage current on the connector body. Protective measures include conformally coating the 895-130-524-507 to mitigate moisture ingress, mechanical strain relief on solder tails, potting of the connector cavity (if permitted by card insertion requirements), and periodic contact resistance monitoring in critical applications. For mission-critical systems, planned connector replacement intervals of 5–10 years should be specified independent of failure occurrence.
  • How does the dual-edge, two-row configuration of the Mercury 895-130-524-507 compare to alternative single-row or high-density connectors for equivalent signal routing capability? The 895-130-524-507 provides 130 positions in a dual-edge format, yielding a connector footprint of approximately 6.5 inches (165mm) in length and 0.3 inches (7.5mm) in height. Alternative connector architectures for equivalent I/O density include: (1) single-row 0.050" pitch connectors offering 260+ positions in similar length but with higher insertion force, contact wear, and crosstalk in dense routing; (2) high-density vertical connectors (such as 0.050" or 0.080" pitch, 2–4 rows) occupying significantly less PCB real estate but requiring specialized test and assembly equipment; and (3) surface-mount edge connectors eliminating through-hole solder stress but introducing different thermal profiling and PCB warpage concerns. The 895-130-524-507 dual-edge approach represents a balance between legacy 0.100" pitch mechanical compatibility and moderate I/O consolidation; it maintains manual assembly feasibility (insertion force <200 N) and standard through-hole PCB processing without requiring advanced fabrication. For applications where PCB space is unconstrained and assembly automation is available, the 895-130-524-507 may offer superior reliability compared to denser 0.050" pitch connectors due to lower contact stress and reduced crosstalk. Conversely, for compact embedded systems or mobile devices prioritizing size reduction over insertion force, migrating to surface-mount high-density connectors (such as 0.050" pitch or BGA-style edge connectors) would reduce footprint by 30–50% but introduce design re-qualification and test interface complexity.
  • What electrical isolation, leakage current, and dielectric strength characteristics should be verified before using the Mercury 895-130-524-507 in mixed-voltage applications or medical/industrial control systems? The 895-130-524-507 datasheet specifies PPS (Polyphenylene Sulfide) insulation material, which exhibits dielectric strength of approximately 3.5–4.0 kV/mm in standard IEC 60243 testing and volume resistivity >10^15 Ω·cm at room temperature. For mixed-voltage applications (e.g., separating 48V industrial DC circuits from 3.3V logic signals on adjacent contacts), the 895-130-524-507 provides no inherent isolation; breakdown voltage between adjacent 0.100" pitch contacts under high humidity or contaminated conditions is typically 2–3 kV, insufficient for Safety Extra Low Voltage (SELV) or reinforced insulation requirements in medical or industrial applications. Surface leakage current on PPS insulation increases exponentially with temperature and humidity; at 125°C and 85% relative humidity (85/85 condition), leakage current may increase 100–1000× above room-temperature values, potentially degrading high-impedance analog signal integrity. If the 895-130-524-507 is deployed in medical devices (e.g., patient-connected equipment) or safety-critical industrial control, creepage and clearance distances must be verified against IEC 60601 (medical) or IEC 61010 (safety) standards; typical requirements mandate 3–6mm clearance and 3–8mm creepage for reinforced insulation, meaning physical card or connector spacing exceeding standard 0.100" pitch must be implemented. Moisture ingress testing (IPC-TM-650 2.3.28 or equivalent) should be conducted on prototype 895-130-524-507 assemblies before production release to confirm leakage current remains <1µA at maximum voltage and temperature extremes.
  • What design considerations apply when integrating the Mercury 895-130-524-507 into test fixtures, measurement equipment, or automated handler interfaces? The 895-130-524-507 female dual-edge connector requires matching male edge-card or probe interface; repeatability of electrical contact and mechanical alignment directly impacts measurement accuracy in test applications. Test fixture design using the 895-130-524-507 must account for contact resistance variation (typically 10–30 mΩ per contact) and temperature coefficient of copper alloy resistance (~0.4%/°C); for precision analog measurement (e.g., DC offset or low-level signal acquisition), contact resistance variation can introduce 0.5–2 mV offset error on 1V full-scale signals. Automated handler systems for the 895-130-524-507 require precise card insertion depth control to ensure reproducible contact engagement; undersized insertion (>0.010" short of full insertion) reduces contact normal force by >20% and introduces intermittent open circuits during vibration. The M3 threaded inserts specified on the 895-130-524-507 provide mechanical retention suitable for test equipment fixturing but require precision drilling and tapping of support brackets; misaligned threads or cross-threaded fasteners risk damaging the connector body and creating intermittent electrical faults. Environmental chamber testing of the 895-130-524-507 (e.g., -40°C thermal soak followed by contact resistance verification) should include a break-in cycle of 10–20 insertion/withdrawal cycles to stabilize contact wear and establish baseline resistance before production use. For high-speed digital testing, the 895-130-524-507 interconnect impedance and propagation delay should be characterized empirically; passive probe interfaces on test fixtures may introduce frequency-dependent attenuation >3 dB above 50 MHz, degrading eye-diagram quality for digital signal validation.
  • How do the Contact Material (Copper Alloy) and 10.0µin gold finish specifications of the Mercury 895-130-524-507 affect long-term corrosion resistance and contact reliability in industrial atmospheric conditions? The 895-130-524-507 specifies copper alloy base material with 10.0µin (0.25µm) gold plating; this thin gold layer provides initial corrosion barrier and contact lubricity but offers limited long-term protection in corrosive environments. Gold thickness of 0.25µm is at the lower end of connector industry standards (typical range 0.50–2.0µm); accelerated corrosion testing (per ASTM B368 salt-spray or IPC-A-610 combined environment testing) predicts gold perforation and copper oxidation within 200–500 hours for the 895-130-524-507 in industrial coastal or chemical processing environments with atmospheric SO₂, H₂S, or Cl₂ exposure. Underneath the gold layer, copper alloy is susceptible to dezincification (if alloy contains zinc) or general oxidation, forming nonconductive copper oxide (Cu₂O, CuO) films that increase contact resistance from baseline 10–20 mΩ to >100 mΩ within months in high-corrosion environments. Mitigation strategies for the 895-130-524-507 in harsh industrial settings include: (1) applying conformal coating (acrylic or urethane) to the connector body to reduce moisture and corrosive gas permeation; (2) specifying higher gold plating thickness (0.50–1.0µm) through manufacturer special order, increasing cost but extending life to 2–5 years in moderate corrosion; (3) periodic contact resistance monitoring and predictive maintenance scheduling; (4) enclosing the connector in sealed backplane cavities with desiccant packs to maintain <50% relative humidity. For marine or offshore applications with continuous salt-air exposure, the 895-130-524-507 standard plating may be insufficient; alternative connectors with nickel-underlayer or composite plating (nickel + gold) should be evaluated.
  • What electromagnetic compatibility (EMC) and shielding considerations apply when the Mercury 895-130-524-507 carries high-frequency or sensitive analog signals in equipment subject to FCC or CE regulatory compliance? The 895-130-524-507 provides no integrated shielding; the dual-edge, open connector design allows electromagnetic radiation from adjacent signal traces to couple into the 130-position signal paths. For equipment subject to FCC Part 15 (unintentional radiators) or CE EN 61326 (industrial EMC), radiated emissions from the 895-130-524-507 interconnect can exceed limits if high-frequency clock signals (>10 MHz) or switching edges (rise time <1 ns) are routed through unshielded paths. Common-mode current on the 895-130-524-507 connector frame (due to incomplete ground return distribution) generates magnetic coupling into external loops, contributing to emissions in the 100 MHz–1 GHz band at 20–40 dBµV/m above baseline limits. Shielding strategy for the 895-130-524-507 should include: (1) placing signal grounds every 3–5 positions along the connector to reduce common-mode impedance and convert differential signals to controlled return paths; (2) routing the connector through a shielded backplane enclosure with ferrite shielding directly behind the 895-130-524-507 mating interface; (3) adding a grounded shield can around the external card-edge connector mating region to attenuate radiated emissions by 10–20 dB across 100 MHz–1 GHz. Differential signaling on the 895-130-524-507 (routing complementary signal pairs on adjacent contacts with dedicated ground returns) reduces common-mode radiation by 15–25 dB compared to single-ended signaling. For sensitive analog applications (e.g., sensor inputs <100 µV amplitude), the 895-130-524-507 should be segregated into dedicated low-impedance signal groups with isolated ground planes and separate shield compartments to prevent crosstalk coupling >1% of signal amplitude.
  • Are there known obsolescence or lifecycle risks associated with the Mercury 895-130-524-507, and what design strategies minimize supply chain vulnerability? The 895-130-524-507 operates at 0.100" (2.54mm) pitch—a legacy standard developed in the 1970s–1980s for computing backplanes (ISA, EISA buses) and test equipment. While 0.100" pitch connectors remain in production for industrial and military applications, the broader connector industry trend favors higher-density 0.050" pitch and surface-mount architectures; suppliers have consolidated from dozens to 3–5 major manufacturers. The Mercury 895-130-524-507 manufacturer (Mercury United Electronics, Inc.) maintains active distribution through industrial electronics channels, but single-sourcing risk exists if the manufacturer discontinues the series or transitions production. Design risk mitigation for the 895-130-524-507 includes: (1) identifying qualified alternative sources (such as equivalent 0.100" pitch dual-edge female connectors from TE Connectivity, Hirose, or Amphenol) and validating mechanical and electrical equivalence through prototype testing; (2) establishing supplier agreements with minimum multi-year production commitments and advance notice (12–24 months) for discontinuation; (3) stockpiling 2–5 years of connector inventory for low-volume or long-lifecycle products (military, aerospace, legacy industrial systems) to bridge supply disruption; (4) designing the PCB footprint and card insertion mechanism to accept multiple qualified connector variants, allowing field replacement or retrofit without board redesign. For new product development, the 895-130-524-507 should be specified only if legacy system compatibility or mechanical form-factor constraints mandate 0.100" pitch; otherwise, migration to current-generation higher-density connectors is recommended to reduce long-term obsolescence risk.
  • *Part No. Manufacturer Target Price(USD) *Request Qty Action
    Add Item

    Enter Your Contact Information

    Submit
    895-130-524-507 Stock895-130-524-507 Price895-130-524-507 Electronics
    895-130-524-507 Components895-130-524-507 Inventory895-130-524-507 Digikey
    Supplier 895-130-524-507Order 895-130-524-507 Online Inquiry 895-130-524-507
    895-130-524-507 Image895-130-524-507 Picture895-130-524-507 PDF
    895-130-524-507 DatasheetDownload 895-130-524-507 DatasheetManufacturer EDAC Inc.
    Related parts for 895-130-524-507
    Image Part Number Description Manufacturer PDF Get a Quote
    895-130-524-803 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-807 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-502 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-508 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-212 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-525-202 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-207 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-504 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-808 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-201 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-202 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-204 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-503 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-802 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-208 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-525-201 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-203 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-812 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-512 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote
    895-130-524-804 CONN EDGE DUAL FML 130POS 0.100 EDAC Inc.
    Get a Quote

    News

    More
    Arm and STMicroelectronics Advance Physical AI Through Cort...

    Building on decades of Arm Cortex-M innovation, Arm and STMicroelectronics are working together to bring intelligence closer to where machines interac...

    Renesas Debuts Flagship RX MCUs on 22 nm Process With Embed...

    Renesas Electronics introduced the RX74M and RX74N, two flagship 32-bit microcontrollers (MCUs) designed for industrial automation and energy infrastr...

    Omnivision Intros Image Sensor Duo Targeting Industrial and...

    Omnivision has expanded its industrial image sensor portfolio with the introduction of two backside-illuminated (BSI) global shutter CMOS sensors, the...

    Google is in talks with Marvell to develop two AI inference...

    On April 19, 2026 (local time), media reports citing sources familiar with the matter revealed that Google, a subsidiary of Alphabet, is in talks with...

    TSMC Advances Panel-Level Packaging Technology; CoPoS Pilot...

    According to *The Business Times*, TSMC’s CoPoS (Chip-on-Panel-on-Substrate) pilot production line began delivering equipment to its R&D team in Febr...

    New Products

    More
    Texas Instruments TPS92542-Q1 Synchronous Boost Controller

    Texas Instruments TPS92542-Q1 Synchronous Boost Controller contains a synchronous boost controller and a two-channel monolithic synchronous buck LED d...

    Toshiba TB67H453 Single Channel H-Bridge Driver

    Toshiba TB67H453 Single Channel H-Bridge Driver has a current monitoring function with voltage feedback from the ISENSE output pin. The device's absol...

    STMicroelectronics STSAFE-A120 Authentication ICs

    STMicroelectronics STSAFE-A120 Authentication ICs are highly secure integrated circuits designed to protect sensitive data and devices through advance...

    STMicroelectronics STSAFE-A Optimized Authentication ICs

    STMicroelectronics STSAFE-A Optimized Authentication ICs leverage advanced cryptographic algorithms and key management techniques to protect sensitive...

    Diodes Incorporated PI3DPX1235Q 64 Crossbar Linear ReDriver

    Diodes Incorporated PI3DPX1235Q 6:4 Crossbar Linear ReDriver supports DP link-training transparent for source-side applications. The PI3DPX1235Q compl...

    Email: Info@ariat-tech.comHK TEL: +852 30501966ADD: Rm 2703 27F Ho King Comm Center 2-16,
    Fa Yuen St MongKok Kowloon, Hong Kong.