ACT20ME26PA
Part Number ACT20ME26PA
Manufacturer TE Connectivity Deutsch Connectors
Description SQUARE FLANGE RECETACLE
Quantity Available 211 pcs in stock
Datasheets 1.ACT20ME26PA.pdf2.ACT20ME26PA.pdf
ACT20ME26PA Price Request Price & Lead Time Online
or Email us: Info@ariat-tech.com
Technical Information of ACT20ME26PA
Manufacturer Part Number ACT20ME26PA Category Connectors, Interconnects
Manufacturer DEUTSCH Connectors / TE Connectivity Description SQUARE FLANGE RECETACLE
Package / Case Bag Quantity Available 211 pcs
Voltage Rating 600VAC, 850VDC Termination Crimp
Shielding Shielded Shell Size, MIL E
Shell Size - Insert 17-26 Shell Material Composite
Shell Finish Electroless Nickel Series MIL-DTL-38999 Series III, ACT
Primary Material Composite Package Bag
Orientation A Operating Temperature -65°C ~ 200°C
Number of Positions 26 Mounting Type Panel Mount
Mounting Feature Flange Material Flammability Rating -
Insert Material Thermoplastic Ingress Protection Environment Resistant
Features - Fastening Type Threaded
Current Rating (Amps) - Contact Material Copper Alloy
Contact Finish Thickness - Mating 50.0µin (1.27µm) Contact Finish - Mating Gold
Connector Type Receptacle, Male Pins Color Silver
Cable Opening - Base Product Number ACT20ME
Backshell Material, Plating - Applications Aviation, Communication Systems, Industrial
ACT20ME26PA are New and Original in Stock, Find ACT20ME26PA electronics components stock, Datasheet, Inventory and Price at Ariat-Tech.com Online, Order ACT20ME26PA TE Connectivity Deutsch Connectors with warrantied and confidence from Ariat Technology Limitd. Ship via DHL/FedEx/UPS. Payment with Wire Transfer or PayPal is OK.
Email us: Info@Ariat-Tech.com or RFQ ACT20ME26PA Online.

Frequently Asked Questions

  • What environmental sealing capabilities does the ACT20ME26PA provide, and how does its composite construction affect connector reliability in harsh industrial or aerospace applications? The ACT20ME26PA is constructed with composite shell materials and features environment-resistant ingress protection, making it suitable for aviation, communication systems, and industrial environments where moisture, vibration, and temperature extremes are present. The composite material resists corrosion more effectively than traditional metal shells in salt-spray or chemically aggressive environments, while the electroless nickel shell finish provides additional protection against oxidation. The 26-position configuration with shielded design maintains signal integrity in high-noise industrial settings. However, composite materials exhibit different thermal expansion characteristics than metals—designers must account for potential stress at connector interfaces during thermal cycling between the -65°C to 200°C operating range, particularly in cryogenic aerospace applications or high-temperature industrial equipment.
  • How do the voltage and temperature ratings of the ACT20ME26PA influence circuit design decisions for high-voltage industrial control systems? The ACT20ME26PA is rated for 600VAC and 850VDC operation across a -65°C to 200°C temperature range, positioning it for industrial motor control, power distribution, and high-voltage switching applications. The 850VDC rating supports DC-link circuits in industrial inverters and renewable energy systems. However, designers must recognize that contact resistance and insulation resistance degrade as temperature approaches 200°C—high-voltage designs should include thermal margin analysis to prevent dielectric breakdown. The crimp termination method demands precise contact pressure specification; over-crimping or under-crimping introduces resistance variation that becomes problematic at maximum voltage ratings. The threaded fastening on the ACT20ME26PA provides vibration-resistant mating but requires periodic inspection in industrial environments where connector cycling is frequent.
  • What specific design considerations apply when integrating the ACT20ME26PA into aerospace avionics harnesses that must meet MIL-DTL-38999 Series III qualification requirements? The ACT20ME26PA conforms to MIL-DTL-38999 Series III specifications, a military circular connector standard widely adopted in aviation for its proven environmental durability and interchangeability. Series III connectors like the ACT20ME26PA undergo rigorous qualification testing for salt-fog corrosion, thermal shock, vibration endurance, and contact retention—critical for aircraft electrical systems where connector failure creates safety risks. The 26-position, size E shell is commonly used in moderately complex avionics subsystems such as environmental control systems, lighting distribution, and sensor interfaces. Designers must verify that the ACT20ME26PA's crimp contact specification matches qualification test data; aerospace supply chains typically maintain traceability documentation proving that specific crimp tool settings produce acceptable pull-force values. The operating temperature range of -65°C to 200°C accommodates high-altitude external fuselage equipment (extreme cold) and equipment bays near engine compartments (high heat), though thermal cycling stress on composite materials requires validation for applications experiencing rapid temperature transients.
  • Does the ACT20ME26PA's composite shell construction offer any advantages or limitations compared to aluminum shells in electromagnetic compatibility (EMC) design for communication systems? The ACT20ME26PA uses a composite shell with electroless nickel finish rather than traditional aluminum, affecting EMC performance in communication systems. The nickel-plated composite provides electromagnetic shielding through its conductive surface while eliminating galvanic corrosion concerns that arise when dissimilar metals interface. However, composite materials exhibit lower electrical conductivity than solid aluminum; designers must verify that the nickel plating thickness and surface continuity maintain shielding effectiveness across the operating frequency range. The ACT20ME26PA's shielded configuration is appropriate for signal integrity in industrial communication equipment, but RF systems operating above 1 GHz require measurement verification that shielding attenuation meets link budget requirements. Composite shells also differ thermally—the ACT20ME26PA experiences slower heat dissipation from internal contacts compared to aluminum alternatives, which can elevate contact temperature in high-current applications operating near the upper thermal limit.
  • What are the functional and reliability implications of the ACT20ME26PA's crimp termination method versus solder or snap-in alternatives for field-replaceable equipment? The ACT20ME26PA employs crimp termination, a mechanically permanent connection requiring specialized tools and operator training but offering several reliability advantages over solder for industrial and aerospace environments. Crimp connections on the ACT20ME26PA eliminate thermal stress from solder reflow, reducing wire fatigue at the connection point during thermal cycling. The crimp joint resists vibration-induced wire fracture better than soldered connections in equipment exposed to continuous mechanical shock. However, crimp quality is operator-dependent; inadequate crimping force on the ACT20ME26PA's copper alloy contacts introduces high contact resistance, while excessive force can fracture the conductor. Unlike snap-in designs that allow rapid field retermination, the ACT20ME26PA requires complete contact replacement if a single position fails—this constrains field serviceability in remote industrial installations. Designers should specify documented crimp tool calibration procedures and possibly include redundant contact positions if single-point connection failure is unacceptable.
  • How does the ACT20ME26PA's 26-position configuration and shell size E rating affect connector density in industrial panel layouts, and what thermal management considerations arise from this density? The ACT20ME26PA provides 26 contacts in a size E shell format, a mid-range density used in industrial control cabinets where physical space is constrained but contact count must accommodate multiple subsystems. Size E of the ACT20ME26PA is significantly smaller than size K connectors (38 positions) but larger than size D (19 positions), making it a practical choice for equipment with moderate wiring complexity. Panel mounting via flange allows the ACT20ME26PA to be integrated into DIN rail enclosures common in industrial automation. However, high-density panel installations create thermal accumulation—multiple ACT20ME26PA connectors mounted in close proximity without adequate airflow can elevate internal contact temperature beyond nameplate ratings. At the upper limit of the 200°C operating range, contact resistance becomes unstable; designers must account for self-heating from I²R losses and ensure adequate ventilation around connector regions.
  • What material compatibility and outgassing characteristics should engineers verify when using the ACT20ME26PA in sealed aerospace cabin or life-support equipment? The ACT20ME26PA's thermoplastic insert material and composite shell are generally compatible with sealed aerospace environments, but designers must verify outgassing profiles per NASA or ESA standards if the connector operates in pressurized cabins or closed-loop life-support systems. Thermoplastic materials can release volatile organic compounds (VOCs) under thermal stress; the ACT20ME26PA operating near its 200°C upper limit may exhibit measurable outgassing that fouls optical surfaces or contaminates sensitive sensors in hermetically sealed avionics bays. The copper alloy contacts and nickel plating are stable under vacuum and do not contribute outgassing. For long-duration aerospace missions, material coupons from the ACT20ME26PA production batch should be tested for total mass loss (TML) and collected volatile condensable materials (CVCM) per ASTM E595. This verification becomes critical for spacecraft, orbital platforms, or high-altitude pressure vessel applications where material outgassing directly impacts mission success.
  • How do the ACT20ME26PA's crimp contact specifications interact with wire gauge selection and current-carrying capacity in industrial power distribution designs? The ACT20ME26PA accepts crimp contacts sized for specific wire gauges; the crimp specification determines the acceptable conductor cross-section and maximum current per contact without exceeding temperature rise limits. Although the datasheet does not specify amperage rating for individual contacts, the voltage rating (600VAC, 850VDC) and operating temperature range (-65°C to 200°C) define the thermal envelope. In practice, industrial designers typically limit current to values where I²R heating keeps contact temperature 10–15°C below the 200°C maximum, leaving thermal margin for ambient temperature swings. The ACT20ME26PA's crimp contact must match the terminated wire gauge precisely; under-sized crimps create high resistance and excessive heating, while oversized crimps result in incomplete wire stranding and poor contact retention. Designers must cross-reference the crimp tool specification with wire gauge tables to ensure repeatable, field-serviceable installations.
  • What are the long-term reliability concerns associated with the ACT20ME26PA's electroless nickel finish in industrial environments experiencing chemical exposure or thermal cycling? The ACT20ME26PA features an electroless nickel shell finish, a common corrosion barrier in industrial connectors. Electroless nickel resists oxidation and provides a stable contact surface, but its durability depends on plating thickness and substrate adhesion. In environments with acid rain, salt spray, or airborne sulfur compounds (common near industrial processing facilities), the electroless nickel on the ACT20ME26PA can develop micropitting over years of operation—this initiates galvanic corrosion if the underlying composite material absorbs moisture. Thermal cycling exacerbates plating stress; repeated excursions through the full -65°C to 200°C range can cause microcracking in the nickel layer, exposing the substrate. For long-life industrial installations (>10 years), designers should specify periodic visual inspection of the ACT20ME26PA connector shell and schedule preventive replacement if pitting or surface discoloration appears. Applications in marine or chemically corrosive environments may require additional conformal coating or environmental sealing beyond the standard ACT20ME26PA design.
  • How does the panel-mount flange design of the ACT20ME26PA affect installation tolerances and mechanical stress in high-vibration equipment? The ACT20ME26PA features a panel-mount flange secured via threaded fastening, a robust installation method for fixed installations in industrial machinery and test equipment. The threaded interface provides excellent vibration resistance compared to snap-fit designs, reducing fretting corrosion at the connector-to-chassis interface. However, the flange design introduces mechanical stress concentration at the mounting holes; inadequate thread engagement or over-torque can crack the composite material around fasteners. Installation tolerances on the ACT20ME26PA are tighter than quick-disconnect connectors—the mounting hole diameter must accommodate standard fasteners without excessive play that allows connector rocking during vibration. In high-vibration environments (>2G continuous), designers should use torque-lock fasteners on the ACT20ME26PA and verify that the installed connector does not exhibit micro-motion against the panel. The threaded fastening also means field replacement of the ACT20ME26PA is less rapid than lever-lock alternatives, affecting maintenance workflows in demanding industrial applications.
  • What contact retention force specifications and pull-test data should designers verify before qualifying the ACT20ME26PA for mission-critical industrial control systems? The ACT20ME26PA employs crimp contacts with specified retention forces that resist accidental contact separation during thermal cycling and vibration exposure. MIL-DTL-38999 Series III specifications require pull-force testing on the ACT20ME26PA's contacts to ensure minimum retention; typical Series III contacts withstand 12–15 lbf pull force before separation. However, pull-force performance degrades as contact temperature rises due to reduced contact spring tension and material stress relaxation. At the ACT20ME26PA's 200°C operating limit, contact retention force may drop 20–30% from room-temperature values, creating risk in applications experiencing simultaneous high temperature and mechanical vibration. Designers of critical systems should obtain pull-force versus temperature curves from the connector supplier and establish a thermal margin—retaining contacts at 200°C with only 50% of room-temperature force introduces unacceptable risk. Vibration environments require additional mechanical stress analysis; the ACT20ME26PA's contact retention must be verified under combined temperature and vibration loading to prevent nuisance disconnections.
  • How does the ACT20ME26PA's RoHS3 compliance and REACH status affect supply chain qualification and long-term obsolescence risk in aerospace and industrial programs? The ACT20ME26PA is RoHS3 compliant and REACH-affected, indicating it meets current environmental regulations in the EU and incorporates restricted substance limitations. RoHS3 compliance means the ACT20ME26PA eliminates lead-based solder and cadmium plating, reducing long-term toxicity concerns. However, RoHS3-compliant materials sometimes exhibit different thermal or mechanical properties compared to legacy non-compliant designs—the ACT20ME26PA's solder-free contacts and lead-free plating may have marginally different contact resistance profiles or thermal fatigue characteristics. REACH compliance obligates the supplier to maintain documentation of substances of concern (SVHC) in the ACT20ME26PA; this documentation is typically available through the supplier's material declaration. For aerospace and industrial programs with multi-year production spans, designers should verify that the ACT20ME26PA supplier commits to material and design continuity—regulatory compliance can drive subtle design iterations that affect compatibility with legacy test data. Long-term supply continuity of the ACT20ME26PA requires explicit supplier agreements and design freeze controls, particularly for small-volume industrial OEM applications.
  • What alternatives to the ACT20ME26PA exist in the MIL-DTL-38999 Series III family, and how should engineers evaluate trade-offs between connector size, position count, and application fit? The ACT20ME26PA represents one configuration within TE Connectivity's MIL-DTL-38999 Series III lineup; alternatives include smaller formats (size D with 19 positions) and larger configurations (size K with 38 positions). Designers selecting between these variants must balance connector density against panel space constraints and harness complexity. The ACT20ME26PA's 26-position, size E configuration suits mid-complexity industrial subsystems; choosing a smaller format like the size D alternative reduces panel real estate but forces circuit designers to split wiring across multiple connectors, increasing failure modes and complicating field maintenance. Conversely, oversizing to a 38-position alternative reduces wiring path count but occupies unnecessary panel space and increases connector cost. The ACT20ME26PA's thermal, vibration, and environmental performance is consistent across Series III family members; selection should be driven purely by contact count and panel layout requirements rather than performance expectations. Cross-compatibility within Series III means the ACT20ME26PA can interface with mating plugs from other manufacturers adhering to the same standard, reducing sole-source risk.
  • How do the ACT20ME26PA's shielding design and composite construction affect signal quality in industrial control networks using analog sensor feedback or low-level digital communication? The ACT20ME26PA incorporates shielding that attenuates external electromagnetic interference, protecting analog and digital signals in industrial control environments. The composite shell with nickel finish supports shield continuity from mating connector to termination point, maintaining noise rejection across the interconnect. However, the effectiveness of shielding on the ACT20ME26PA depends on proper grounding of the shield at both connector ends; inadequate shield termination negates the shielding benefit and can create ground loops in analog sensor circuits. Industrial systems using the ACT20ME26PA for 4–20 mA current loops or 0–10V analog signals should implement differential signal routing with shield grounding per IEC 61000-6-2 industrial EMC standards. For digital communication (CAN, Profibus, Modbus), the ACT20ME26PA's shielding attenuates switching noise from power electronics operating in the same cabinet, reducing bit-error rates in long cable runs. Designers should measure insertion loss and shielding effectiveness of the ACT20ME26PA at the operating frequency band to confirm performance margins above noise immunity thresholds.
  • What design verification testing should be specified for the ACT20ME26PA when deployed in outdoor industrial environments or portable test equipment experiencing extreme thermal and moisture cycling? Outdoor deployments and portable equipment using the ACT20ME26PA face thermal cycling from -65°C to +200°C range extremes plus moisture ingress during humidity transients. Design verification should include: (1) salt-fog corrosion testing per ASTM B117 to simulate coastal or chemical-plant environments and verify electroless nickel durability on the ACT20ME26PA shell; (2) thermal shock cycling (-65°C to +200°C, multiple cycles) to assess composite material stress and contact retention force stability over the operating life; (3) moisture ingress testing via humidity chamber exposure to verify the ACT20ME26PA's environment-resistant rating under prolonged wet conditions; (4) vibration endurance per MIL-STD-810 to confirm the ACT20ME26PA's threaded fasteners remain tight and contacts do not work loose under transportation and field use. These verification tests are distinct from initial manufacturer qualification; field-specific testing validates that the ACT20ME26PA performs reliably in the actual deployment environment. Test data from the ACT20ME26PA should be archived and reviewed during design reviews to identify any drift in performance or emerging failure modes during early production runs.
  • *Part No. Manufacturer Target Price(USD) *Request Qty Action
    Add Item

    Enter Your Contact Information

    Submit
    ACT20ME26PA StockACT20ME26PA PriceACT20ME26PA Electronics
    ACT20ME26PA ComponentsACT20ME26PA InventoryACT20ME26PA Digikey
    Supplier ACT20ME26PAOrder ACT20ME26PA Online Inquiry ACT20ME26PA
    ACT20ME26PA ImageACT20ME26PA PictureACT20ME26PA PDF
    ACT20ME26PA DatasheetDownload ACT20ME26PA DatasheetManufacturer DEUTSCH Connectors / TE Connectivity
    Related parts for ACT20ME26PA
    Image Part Number Description Manufacturer PDF Get a Quote
    ACT20ME26JE-6149 [V001] SQUARE FLANGE RECEPTACLE TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26PC [V001] SQUARE FLANGE RECEPTACLE TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26PB-6149 [V001] SQUARE FLANGE RECEPTACLE TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26JD [V001] SHELL RECP TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26JE-6149 SQUARE FLANGE RECETACLE TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26JN [V001] SHELL RECP TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26PB [V001] SQUARE FLANGE RECEPTACLE TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26PD [V001] SQUARE FLANGE RECEPTACLE TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26JN-6149 SQUARE FLANGE RECETACLE TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26PA-6149 [V001] SQUARE FLANGE RECEPTACLE TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26JD-6149 [V001] SQUARE FLANGE RECEPTACLE TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26JE [V001] SHELL RECP TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26JN-6149 [V001] SQUARE FLANGE RECEPTACLE TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26PD-6149 [V001] SQUARE FLANGE RECEPTACLE TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26PB SQUARE FLANGE RECETACLE TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26PA [V001] SQUARE FLANGE RECEPTACLE TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26PC SQUARE FLANGE RECETACLE TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26PC-6149 [V001] SQUARE FLANGE RECEPTACLE TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26JN SQUARE FLANGE RECETACLE TE Connectivity Deutsch Connectors
    Get a Quote
    ACT20ME26JE SQUARE FLANGE RECETACLE TE Connectivity Deutsch Connectors
    Get a Quote

    News

    More
    Renesas Debuts Flagship RX MCUs on 22 nm Process With Embed...

    Renesas Electronics introduced the RX74M and RX74N, two flagship 32-bit microcontrollers (MCUs) designed for industrial automation and energy infrastr...

    Omnivision Intros Image Sensor Duo Targeting Industrial and...

    Omnivision has expanded its industrial image sensor portfolio with the introduction of two backside-illuminated (BSI) global shutter CMOS sensors, the...

    Google is in talks with Marvell to develop two AI inference...

    On April 19, 2026 (local time), media reports citing sources familiar with the matter revealed that Google, a subsidiary of Alphabet, is in talks with...

    TSMC Advances Panel-Level Packaging Technology; CoPoS Pilot...

    According to *The Business Times*, TSMC’s CoPoS (Chip-on-Panel-on-Substrate) pilot production line began delivering equipment to its R&D team in Febr...

    Anthropic Partners with Google and Broadcom to Deploy Sever...

    On April 6 local time, U.S. artificial intelligence (AI) technology giant Anthropic announced that it has signed a new agreement with Google and Broad...

    New Products

    More
    Texas Instruments TPS92542-Q1 Synchronous Boost Controller

    Texas Instruments TPS92542-Q1 Synchronous Boost Controller contains a synchronous boost controller and a two-channel monolithic synchronous buck LED d...

    Toshiba TB67H453 Single Channel H-Bridge Driver

    Toshiba TB67H453 Single Channel H-Bridge Driver has a current monitoring function with voltage feedback from the ISENSE output pin. The device's absol...

    STMicroelectronics STSAFE-A120 Authentication ICs

    STMicroelectronics STSAFE-A120 Authentication ICs are highly secure integrated circuits designed to protect sensitive data and devices through advance...

    STMicroelectronics STSAFE-A Optimized Authentication ICs

    STMicroelectronics STSAFE-A Optimized Authentication ICs leverage advanced cryptographic algorithms and key management techniques to protect sensitive...

    Diodes Incorporated PI3DPX1235Q 64 Crossbar Linear ReDriver

    Diodes Incorporated PI3DPX1235Q 6:4 Crossbar Linear ReDriver supports DP link-training transparent for source-side applications. The PI3DPX1235Q compl...

    Email: Info@ariat-tech.comHK TEL: +852 30501966ADD: Rm 2703 27F Ho King Comm Center 2-16,
    Fa Yuen St MongKok Kowloon, Hong Kong.