CC1-B0-34-635-634-C
Part Number CC1-B0-34-635-634-C
Manufacturer Carling Technologies
Description CIRCUIT BREAKER
Quantity Available 546 pcs new original in stock.
Request Stock & Quotation
Datasheets
CC1-B0-34-635-634-C Price Request Price & Lead Time Online
or Email us: Info@ariat-tech.com
Technical Information of CC1-B0-34-635-634-C
Manufacturer Part Number CC1-B0-34-635-634-C Category Circuit Protection
Manufacturer Carling Technologies Description CIRCUIT BREAKER
Package / Case Bulk Quantity Available 546 pcs
Voltage Rating - DC 125 V Voltage Rating - AC 480 V
Series C Package Bulk
Number of Poles 1 Mounting Type Panel Mount
Illumination Voltage (Nominal) - Illumination None
Current Rating (Amps) 35A Breaker Type Magnetic (Hydraulic Delay)
Approval Agency CCC, CSA, UL Actuator Type Rocker
CC1-B0-34-635-634-C are New and Original in Stock, Find CC1-B0-34-635-634-C electronics components stock, Datasheet, Inventory and Price at Ariat-Tech.com Online, Order CC1-B0-34-635-634-C Carling Technologies with warrantied and confidence from Ariat Technology Limitd. Ship via DHL/FedEx/UPS. Payment with Wire Transfer or PayPal is OK.
Email us: Info@Ariat-Tech.com or RFQ CC1-B0-34-635-634-C Online.

Frequently Asked Questions

  • How does the hydraulic delay mechanism in the CC1-B0-34-635-634-C affect trip response time during overload conditions? The CC1-B0-34-635-634-C combines magnetic and hydraulic delay technologies to provide two distinct protection modes. The magnetic element responds instantly to short circuits, while the hydraulic delay mechanism moderates response to sustained overloads by using viscous fluid resistance. This dual approach prevents nuisance trips from brief inrush currents common in motor startup or transformer energization, while maintaining fast fault detection. The hydraulic delay is temperature-dependent, meaning response time increases in cold environments and decreases in warm conditions—a critical consideration for equipment installed in uncontrolled outdoor or industrial spaces.
  • What circuit architectures and load types are most suitable for the 35A rating and dual-voltage design of the CC1-B0-34-635-634-C? The CC1-B0-34-635-634-C 35A capacity with 480V AC and 125V DC ratings positions it for three-phase industrial AC distribution circuits and DC control circuits within the same equipment enclosure. The AC rating addresses feeder protection for motors, heating elements, and process equipment in industrial plants, while the 125V DC rating supports auxiliary control circuits, solenoid valve coils, or DC motor circuits common in manufacturing automation. Single-pole configuration means the CC1-B0-34-635-634-C protects one phase or one DC return path; three-phase circuits require three separate units. This design is less suitable for residential lighting or low-voltage consumer electronics where lower current ratings predominate.
  • How do the CCC, CSA, and UL certifications of the CC1-B0-34-635-634-C affect compliance requirements for different regional markets? The CC1-B0-34-635-634-C carries UL (Underwriters Laboratories) approval, mandatory for electrical safety in North American installations, CSA (Canadian Standards Association) approval for Canadian industrial equipment, and CCC (China Compulsory Certification) approval for export into mainland Chinese markets. Each certification verifies the CC1-B0-34-635-634-C meets breaking capacity, thermal stability, and contact durability standards specific to each region. Equipment designers and system integrators should verify whether local adoption of these standards is contractually required—some regional procurement standards mandate CSA approval even outside Canada, while others accept UL alone. The presence of all three certifications reduces redesign risk when expanding product distribution.
  • What is the relationship between the rocker actuator design and panel-mount configuration of the CC1-B0-34-635-634-C in operator-accessible control panels? The rocker actuator on the CC1-B0-34-635-634-C provides tactile feedback and intuitive on-off positioning suitable for operator intervention in industrial control enclosures. Panel mounting positions the CC1-B0-34-635-634-C flush with the enclosure faceplate, allowing operators to visually confirm breaker state (handle-up for on, handle-down for off) without opening the cabinet. This configuration supports rapid response during process interruptions or emergency shutdowns. However, the rocker mechanism requires approximately 10-15mm of panel thickness and clear operating space—tight panel layouts or retrofit installations into existing cabinets may require enclosure modification. Contrast this with toggle or pushbutton actuators that occupy less space but provide less tactile feedback.
  • Does the CC1-B0-34-635-634-C require external arc suppression or snubber circuits when switching inductive loads? The CC1-B0-34-635-634-C contacts are designed to break AC loads up to 480V and DC loads up to 125V, with breaking capacity sufficient for typical industrial circuits including motors with moderate inrush current. However, when the CC1-B0-34-635-634-C interrupts highly inductive DC circuits (such as solenoid coils or large relay windings), or when AC circuits contain significant reactive components, arc formation across the contacts accelerates contact erosion. External RC snubber networks (typically 0.1µF capacitor in series with 100Ω resistor across the load) reduce voltage transients and extend contact life. The CC1-B0-34-635-634-C does not integrate internal arc suppression, making snubber evaluation essential during schematic design for DC applications.
  • How does single-pole configuration limit the CC1-B0-34-635-634-C compared to multi-pole alternatives in three-phase motor protection applications? The CC1-B0-34-635-634-C protects a single conductor—one phase in a three-phase circuit or one DC line. Three-phase motor circuits require three CC1-B0-34-635-634-C units, one per phase, coordinated through common mechanical linkages (available separately) to ensure all phases disconnect simultaneously during a fault. Alternatively, three-pole breakers trip all phases with a single actuator mechanism. While three separate CC1-B0-34-635-634-C units offer flexibility (different settings per phase if needed) and reduce inventory complexity for standardized single-pole designs, they increase panel space, wiring complexity, and cost compared to integrated three-pole solutions. Equipment with limited cabinet space often adopts three-pole breakers despite higher per-unit cost.
  • What maintenance or replacement intervals does the hydraulic delay mechanism in the CC1-B0-34-635-634-C impose? The hydraulic fluid in the CC1-B0-34-635-634-C has finite viscosity stability; over 5-10 years, fluid degradation alters trip response characteristics, particularly in hot environments (above 50°C continuous operation). The CC1-B0-34-635-634-C is not field-serviceable—the hydraulic chamber is sealed and cannot be refilled. Preventive replacement during major equipment overhauls (typically 8-15 year intervals depending on environmental exposure) maintains predictable protection response. Without scheduled replacement, the CC1-B0-34-635-634-C may exhibit delayed trips or premature nuisance trips as the hydraulic mechanism ages. This lifecycle cost differs from solid-state electronic breakers, which have longer operating life but higher initial cost.
  • How do temperature extremes affect the trip behavior and breaking capacity of the CC1-B0-34-635-634-C? The hydraulic delay in the CC1-B0-34-635-634-C exhibits significant temperature coefficient. At 0°C, the hydraulic fluid becomes more viscous, extending trip delay by 30-50% compared to rated 20°C operation; at 50°C ambient, trip delay shortens by 25-40%. The magnetic trip element is less temperature-dependent but still shows slight variation. Specifications for the CC1-B0-34-635-634-C typically assume 20°C reference; outdoor installations in cold climates or unventilated enclosures in warm facilities require thermal derating analysis. If the CC1-B0-34-635-634-C operates continuously at 50°C or higher, protective coordination with upstream breakers becomes difficult because the CC1-B0-34-635-634-C trips faster than nominal curves predict. Thermal modeling during system design prevents unexpected protective zone miscoordination.
  • What distinguishes the magnetic trip element of the CC1-B0-34-635-634-C from the hydraulic delay in responding to different fault types? The CC1-B0-34-635-634-C magnetic element responds to current spikes within milliseconds—appropriate for bolted three-phase faults where current jumps to 10× or more above rated current. The hydraulic delay moderates response to currents in the 1.5-3× overload range, preventing trips from startup inrush lasting seconds. This separation enables the CC1-B0-34-635-634-C to distinguish between normal transients and genuine faults. Pure magnetic breakers trip instantly on any overcurrent, causing nuisance trips on motor startup. Pure thermal breakers respond too slowly to short circuits. The combination in the CC1-B0-34-635-634-C balances these concerns, making it suitable for circuits where both inrush immunity and rapid fault clearing are required.
  • Is the CC1-B0-34-635-634-C suitable for direct replacement of older single-pole breakers in retrofit or modernization projects? Direct substitution of the CC1-B0-34-635-634-C into existing panel cutouts depends on panel mounting dimensions, actuator clearance, and terminal type compatibility. The rocker actuator on the CC1-B0-34-635-634-C requires approximately 12-15mm of handle throw; cabinets with tightly-spaced adjacent breakers or limited faceplate access may not accommodate the CC1-B0-34-635-634-C without modification. Terminal connection type (screw, bayonet, or plug-in) must match existing wiring; mismatches require expensive rewiring. Additionally, the CC1-B0-34-635-634-C trip curve differs from older electromechanical designs; protective coordination with upstream utility or generator-fed breakers must be recalculated to ensure the CC1-B0-34-635-634-C trips in proper sequence. A retrofit audit should confirm mechanical fit, electrical compatibility, and coordination before proceeding.
  • How does the 480V AC rating of the CC1-B0-34-635-634-C compare to standard 277V or 380V industrial ratings, and what application boundaries exist? The CC1-B0-34-635-634-C 480V AC rating accommodates North American three-phase industrial distribution systems (480V 3-phase is standard in most large factories, data centers, and heavy manufacturing). European or Asian installations typically use 380V or 400V three-phase systems. The CC1-B0-34-635-634-C cannot be directly applied to lower-voltage systems; applying 480V-rated breaker to 380V circuit is electrically valid but wastes arc-quenching capability and creates unnecessary cost. Conversely, a 380V-rated breaker applied to 480V violates its duty rating and creates arc-over risk. Geographic equipment deployment or multi-region product support must standardize on either the CC1-B0-34-635-634-C (for North America) or alternative regional variants, not mix ratings within the same product line.
  • What breaking capacity does the CC1-B0-34-635-634-C provide, and how does this affect coordination with feeder-level protection? The CC1-B0-34-635-634-C datasheet should specify its Interrupting Capacity (IC) or breaking capacity in kA (kiloamperes) at 480V AC and 125V DC. Typical values range from 10-20 kA for industrial breakers of this class. If a fault current exceeds the CC1-B0-34-635-634-C breaking capacity, the breaker contacts weld or explode, failing to clear the fault and potentially cascading damage upstream. System designers must calculate maximum available fault current at the CC1-B0-34-635-634-C installation location (using transformer impedance, cable length, and source impedance) and confirm this current remains below the CC1-B0-34-635-634-C rating. High-impedance circuits (long feeders, undersized transformers) naturally reduce available fault current; high short-circuit sources (utility-fed substations, large generators) may require breakers with higher IC ratings than the CC1-B0-34-635-634-C provides, necessitating series current-limiting reactors or higher-rated upstream devices.
  • Does the CC1-B0-34-635-634-C integrate or require external status indication beyond the rocker handle position? The CC1-B0-34-635-634-C has no integrated illumination or electronic status signaling—the rocker position (up/down) is the only visual indication. Industrial control systems requiring remote trip status monitoring, alarm logging, or integration with SCADA/PLC systems cannot directly interface the CC1-B0-34-635-634-C without auxiliary mechanical linkages or external current-sensing relays. Modern applications increasingly adopt electronic circuit monitors or solid-state breakers with integrated communication (Ethernet, analog feedback). If the CC1-B0-34-635-634-C system requires status reporting, auxiliary contacts must be added as separate devices, increasing complexity and cost. This mechanical-only design suits standalone protection but limits integration into modern networked equipment.
  • How does ROHS3 compliance of the CC1-B0-34-635-634-C affect contact material selection and long-term reliability? The CC1-B0-34-635-634-C ROHS3 compliance eliminates lead, mercury, cadmium, and other restricted substances from solder, plating, and contact surfaces. Alternative contact materials (often silver alloys or cadmium-free alternatives) substitute for historically reliable cadmium-silver combinations. These alternatives generally perform adequately but exhibit different arc characteristics, contact resistance evolution, and wear profiles. Long-term field data on ROHS3-compliant contacts remains limited compared to legacy designs. The CC1-B0-34-635-634-C should be evaluated in the application environment (AC vs. DC, resistive vs. inductive loads, switching frequency) to confirm contact durability matches the system lifecycle. High-frequency switching or harsh environments may reveal contact degradation sooner than legacy designs, potentially affecting maintenance intervals and inventory planning.
  • What factors determine whether the CC1-B0-34-635-634-C or an electronic solid-state breaker should be selected for a new system design? The CC1-B0-34-635-634-C magnetic-hydraulic mechanism offers simplicity, no external power supply requirement, and proven reliability in stable thermal environments. Solid-state electronic breakers provide faster response, remote monitoring, programmable trip curves, and immunity to thermal drift. Cost favors the CC1-B0-34-635-634-C at lower unit volumes; electronic breakers amortize development cost over larger production runs. Environmental constraints differ: the CC1-B0-34-635-634-C hydraulic mechanism degrades in extreme temperature swings; electronic breakers tolerate wider ranges but require thermal management. System redundancy expectations also influence choice—the CC1-B0-34-635-634-C failure mode is mechanical (contact welding or erosion); electronic breaker failure modes include firmware errors or power supply faults. A hybrid approach (mechanical main breaker with electronic monitoring) balances reliability and diagnostics for critical applications.
  • *Part No. Manufacturer Target Price(USD) *Request Qty Action
    Add Item

    Enter Your Contact Information

    Submit
    CC1-B0-34-635-634-C StockCC1-B0-34-635-634-C PriceCC1-B0-34-635-634-C Electronics
    CC1-B0-34-635-634-C ComponentsCC1-B0-34-635-634-C InventoryCC1-B0-34-635-634-C Digikey
    Supplier CC1-B0-34-635-634-COrder CC1-B0-34-635-634-C Online Inquiry CC1-B0-34-635-634-C
    CC1-B0-34-635-634-C ImageCC1-B0-34-635-634-C PictureCC1-B0-34-635-634-C PDF
    CC1-B0-34-635-634-C DatasheetDownload CC1-B0-34-635-634-C DatasheetManufacturer Carling Technologies
    Related parts for CC1-B0-34-635-634-C
    Image Part Number Description Manufacturer PDF Get a Quote
    CC1-B0-34-625-3F4-C CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-34-660-634-C CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-34-640-634-C CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-34-650-634-C CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-34-660-611-D CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-34-640-1AA-D CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-34-630-634-C CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-34-650-14A-C CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-26-670-33B-KG CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-34-660-3B1-C CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-26-650-31A-KG CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-34-660-3F4-C CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-34-660-611-C CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-34-625-3G1-C CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-26-660-33B-KG CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-34-625-5JA-C CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-34-610-111-C CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-34-640-1AA-C CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-32-660-331-C CIRCUIT BREAKER Carling Technologies  
    Get a Quote
    CC1-B0-34-620-3G1-C CIRCUIT BREAKER Carling Technologies  
    Get a Quote

    News

    More
    onsemi Unveils EliteSiC M4 SiC Platform

    onsemi has launched EliteSiC M4, its fourth-generation silicon carbide (SiC) platform based on a trench architecture designed to improve next-generati...

    Arm and STMicroelectronics Advance Physical AI Through Cort...

    Building on decades of Arm Cortex-M innovation, Arm and STMicroelectronics are working together to bring intelligence closer to where machines interac...

    Renesas Debuts Flagship RX MCUs on 22 nm Process With Embed...

    Renesas Electronics introduced the RX74M and RX74N, two flagship 32-bit microcontrollers (MCUs) designed for industrial automation and energy infrastr...

    Omnivision Intros Image Sensor Duo Targeting Industrial and...

    Omnivision has expanded its industrial image sensor portfolio with the introduction of two backside-illuminated (BSI) global shutter CMOS sensors, the...

    Google is in talks with Marvell to develop two AI inference...

    On April 19, 2026 (local time), media reports citing sources familiar with the matter revealed that Google, a subsidiary of Alphabet, is in talks with...

    New Products

    More
    Texas Instruments TPS92542-Q1 Synchronous Boost Controller

    Texas Instruments TPS92542-Q1 Synchronous Boost Controller contains a synchronous boost controller and a two-channel monolithic synchronous buck LED d...

    Toshiba TB67H453 Single Channel H-Bridge Driver

    Toshiba TB67H453 Single Channel H-Bridge Driver has a current monitoring function with voltage feedback from the ISENSE output pin. The device's absol...

    STMicroelectronics STSAFE-A120 Authentication ICs

    STMicroelectronics STSAFE-A120 Authentication ICs are highly secure integrated circuits designed to protect sensitive data and devices through advance...

    STMicroelectronics STSAFE-A Optimized Authentication ICs

    STMicroelectronics STSAFE-A Optimized Authentication ICs leverage advanced cryptographic algorithms and key management techniques to protect sensitive...

    Diodes Incorporated PI3DPX1235Q 64 Crossbar Linear ReDriver

    Diodes Incorporated PI3DPX1235Q 6:4 Crossbar Linear ReDriver supports DP link-training transparent for source-side applications. The PI3DPX1235Q compl...

    Email: Info@ariat-tech.comHK TEL: +852 30501966ADD: Rm 2703 27F Ho King Comm Center 2-16,
    Fa Yuen St MongKok Kowloon, Hong Kong.