Technical Information of GMB63H1PC13
Manufacturer Part Number GMB63H1PC13 Category Circuit Protection
Manufacturer Carlo Gavazzi Description CIR BRKR THERM-MAG 13A 480/277V
Package / Case Box Quantity Available 1134 pcs
Voltage Rating - AC 480 V Series GMB63
Package Box Number of Poles 1
Mounting Type DIN Rail Illumination Voltage (Nominal) -
Illumination None Current Rating (Amps) 13A
Breaker Type Thermal Magnetic Base Product Number GMB63H1
Approval Agency CSA C22.2 No 5, IEC 60947-2, UL489 Actuator Type Lever
DownloadGMB63H1PC13 PDF - DE.pdf
GMB63H1PC13 are New and Original in Stock, Find GMB63H1PC13 electronics components stock, Datasheet, Inventory and Price at Ariat-Tech.com Online, Order GMB63H1PC13 Carlo Gavazzi Inc. with warrantied and confidence from Ariat Technology Limitd. Ship via DHL/FedEx/UPS. Payment with Wire Transfer or PayPal is OK.
Email us: Info@Ariat-Tech.com or RFQ GMB63H1PC13 Online.

Frequently Asked Questions

  • What are the thermal and magnetic trip characteristics of the GMB63H1PC13, and how do these affect coordination with upstream protection devices? The GMB63H1PC13 employs a dual-element trip mechanism where the thermal element responds to sustained overcurrent conditions and the magnetic element provides instantaneous protection during fault events. The thermal curve operates over a time-current range designed to coordinate with utility-grade protection upstream while the magnetic threshold delivers high-speed interruption for short circuits. This dual mechanism is essential in 480V industrial systems where selective coordination prevents unnecessary shutdowns of downstream circuits during transient faults. The interaction between thermal and magnetic trip points determines how the GMB63H1PC13 responds to different fault signatures; a purely thermal response may be too slow for semiconductor protection, while purely magnetic behavior would nuisance trip on inrush currents. Understanding this relationship is critical when designing motor control centers or distribution panels where multiple GMB63H1PC13 breakers operate in series.
  • How does the 13A current rating of the GMB63H1PC13 compare to typical motor branch circuit protection requirements, and what load scenarios drive this specific rating selection? The 13A rating of the GMB63H1PC13 typically protects circuits with approximately 10–12 kW motor loads at 480V three-phase operation or lower-power single-phase industrial applications. This intermediate rating fills a common gap in motor protection where standard 10A breakers may be insufficient for motor inrush tolerance while 15A breakers provide inadequate overload margin. The GMB63H1PC13 is selected when branch circuits must coordinate with feeder protection rated at 15–20A while still providing dedicated overload protection to the motor or equipment. In practice, the 13A thermal threshold ensures that the GMB63H1PC13 can tolerate typical motor starting transients—which may briefly exceed nameplate current by 600–800%—while clearing genuine overload conditions within the motor's thermal time constant.
  • What is the significance of dual-voltage rating (480V AC/DC) on the GMB63H1PC13, and what additional design considerations apply to DC circuit protection? The GMB63H1PC13 is rated for both 480V AC and DC operation, which expands application flexibility but introduces different protection physics. AC circuits benefit from natural zero-crossing current elimination, which aids arc quenching and reduces contact erosion. DC circuits, however, sustain the arc during fault conditions because there is no natural current zero, requiring the GMB63H1PC13 magnetic mechanism to forcibly separate contacts under higher stress. This difference means that DC systems using the GMB63H1PC13 may experience more aggressive contact wear per fault event and require attention to contact material compatibility and replacement intervals. Additionally, DC systems demand careful consideration of the GMB63H1PC13's voltage rating at the expected system voltage; 480V DC applications operate near the rated limit, leaving minimal margin for transient overvoltages from inductive load switching.
  • How does the single-pole configuration of the GMB63H1PC13 influence its use in three-phase industrial systems, and when is additional protection coordination necessary? The GMB63H1PC13 is a single-pole device, meaning it protects only one phase conductor. In three-phase 480V systems, single-pole protection is typically applied to individual phase legs within a larger three-pole distribution architecture, or used for dedicated single-phase branch circuits derived from a three-phase service. Using the GMB63H1PC13 for single-phase loads requires that phase-to-neutral or phase-to-ground fault currents still flow through the breaker's magnetic trip element; however, true three-phase faults between phases may not be detected by a single-pole GMB63H1PC13 if the breaker is installed on only one phase. This limitation necessitates upstream three-pole protection (such as a three-pole main breaker) to handle multi-phase faults. In addition, single-pole breakers like the GMB63H1PC13 do not provide the mechanical or electrical interlock of three-pole devices, so careful circuit design is needed to prevent energized-conductor hazards during maintenance.
  • What mechanical and electrical stresses does lever actuation of the GMB63H1PC13 impose compared to push-button or solenoid-actuated alternatives? The GMB63H1PC13 uses manual lever actuation, providing direct human feedback during trip and reset operations. Lever mechanisms are mechanically simple and reliable, with fewer failure modes than solenoid trips, but require operator presence and intentional action to reset the breaker after a fault. This manual design is appropriate for branch-level protection in accessible control panels where trained personnel monitor circuit status. The lever actuation of the GMB63H1PC13 also means there is no electrical or remote command capability; the breaker cannot be tripped or reset remotely without additional relay hardware. In contrast, electronically actuated or solenoid-trip breakers allow predictive shutdown during system diagnostics or fault escalation procedures. The choice to use the GMB63H1PC13 with lever control implies that the protected circuit's fault handling is inherently local and that nuisance trips are acceptable operational events rather than system-critical faults.
  • How do the CSA C22.2 No 5 and IEC 60947-2 certifications on the GMB63H1PC13 affect its suitability for different geographic or regulatory markets? The GMB63H1PC13 carries CSA (Canadian Standards Association) C22.2 No 5 and IEC 60947-2 (International Electrotechnical Commission) certifications in addition to UL489 (Underwriters Laboratories). CSA C22.2 No 5 is the Canadian equivalent of UL489 and governs circuit breaker safety and performance in Canada and regions following Canadian electrical codes. IEC 60947-2 is the international standard for low-voltage circuit breakers and is used throughout Europe, Asia, and many emerging markets. UL489 certification ensures compliance with North American National Electrical Code (NEC) requirements. The presence of all three certifications on the GMB63H1PC13 indicates it is suitable for installation in North America, Canada, and IEC-compliant jurisdictions. However, this multi-certification approach also means the GMB63H1PC13 must satisfy the more stringent requirements across all three standards, which can limit performance optimization for any single region. Engineers specifying the GMB63H1PC13 should verify that local electrical inspectors recognize these particular certifications before installation.
  • What thermal stability and ambient temperature limits apply to the GMB63H1PC13, and how do high-temperature environments affect trip point calibration? The thermal element of the GMB63H1PC13 relies on bimetallic or similar temperature-sensitive mechanisms to detect sustained overcurrent. Ambient temperature shifts will bias this thermal response; a hot installation environment may cause the GMB63H1PC13 thermal element to trip at lower load currents due to pre-heating, while cold environments may require higher currents to reach trip threshold. Typical industrial-grade breakers like the GMB63H1PC13 are calibrated for a reference ambient of 20–25°C and may exhibit 5–10% variation in trip point per 10°C deviation. In applications where the GMB63H1PC13 is mounted in a confined panel or heated enclosure, this thermal drift becomes design-relevant; protective coordination calculations must account for worst-case temperature scenarios. If the GMB63H1PC13 is installed in an outdoor cabinet or uncontrolled temperature environment, seasonal variations may cause the breaker to nuisance trip during winter low-load periods or fail to trip adequately during summer high-ambient faults.
  • What is the relationship between the GMB63H1PC13's DIN rail mounting form factor and its thermal dissipation characteristics in packed panel layouts? The GMB63H1PC13 is designed for DIN rail mounting, a compact modular architecture that allows multiple breakers to be densely packed along a rail in industrial control panels. This form factor maximizes space efficiency but creates thermal coupling between adjacent breakers on the same rail. Each breaker dissipates heat during load carry and fault events; in a densely populated rail, the cumulative heating can raise the local ambient temperature surrounding the GMB63H1PC13, causing the thermal element to drift from its calibrated setpoint. Panel designers must account for this by ensuring adequate panel ventilation, avoiding back-to-back placement of high-current breakers, or spacing the GMB63H1PC13 breaker away from other heat sources. Additionally, the DIN rail itself conducts heat along its length, so a faulted breaker downstream on the rail can heat the GMB63H1PC13 if it is positioned upstream. Manufacturers typically specify allowable panel temperatures and derating factors for closely-spaced DIN rail breakers; failure to account for these thermal interactions can lead to nuisance trips or false coordination margins.
  • How does the GMB63H1PC13 perform during repetitive fault events or high-frequency switching cycles, and what maintenance intervals are recommended? Each time the GMB63H1PC13 trips a fault, its internal contacts are subjected to arcing and erosion. During AC fault events, the arc extinguishes naturally at current zero crossings; during DC events, the arc persists and causes more aggressive contact material removal per event. The GMB63H1PC13 is rated for a specific number of mechanical and electrical cycles; typical industrial breakers are designed for 10,000–20,000 mechanical operations and fewer electrical interruptions at rated voltage and current. In systems where the GMB63H1PC13 experiences frequent nuisance trips due to poor coordination or inrush transients, contact erosion accelerates, gradually increasing contact resistance and reducing trip reliability. Over time, a heavily-used GMB63H1PC13 may exhibit delayed thermal response or fail to interrupt high faults due to contact degradation. Preventive maintenance for the GMB63H1PC13 involves periodic visual inspection for contact pitting, functional testing to confirm trip response within specification, and eventual replacement if the breaker has sustained a known high-energy fault or accumulated several hundred fault events.
  • What arc quenching and contact material specifications are employed in the GMB63H1PC13, and how do these affect performance in applications with varying X/R ratios or source impedance? The GMB63H1PC13 incorporates arc extinction technology appropriate to its 13A rating and 480V class. Typical designs use arc chutes or ferromagnetic arcing chambers to split the arc into multiple shorter arcs across higher impedance paths, facilitating faster voltage rise across the contacts and arc extinction. The contact material (commonly silver cadmium oxide or alternative compositions compliant with RoHS) balances electrical conductivity with erosion resistance. In systems with low X/R ratios (such as utility-supplied distribution with low source impedance), the fault current rises and falls steeply, allowing the GMB63H1PC13 arc to extinguish quickly at the current zero crossing. Conversely, in systems with high X/R ratios (such as generator-backed supplies or long feeder runs), the fault current may persist past the natural zero crossing, requiring the GMB63H1PC13 magnetic mechanism to force contact separation against higher arc pressure. The GMB63H1PC13 is rated for specific interrupting capacity at 480V; if the actual available fault current exceeds this capacity, the breaker may fail to interrupt cleanly or sustain contact fusion. Therefore, design engineers must verify the available fault current at the point where the GMB63H1PC13 is installed and confirm it remains within the breaker's interrupting rating.
  • Can the GMB63H1PC13 be used for branch protection of HVAC compressor motors or soft-starter-based variable frequency drive circuits, or are different thermal-magnetic characteristics required? The GMB63H1PC13 thermal-magnetic design is optimized for general industrial loads with conventional inrush profiles. HVAC compressor motors present a boundary case: hermetic compressors draw inrush currents of 3–5× nameplate during soft-start ramp but settle quickly. The GMB63H1PC13's thermal element is designed to tolerate brief inrush spikes without nuisance tripping, provided the steady-state motor current remains below approximately 80% of the 13A breaker rating (i.e., ~10.4A). For a 10 kW compressor motor at 480V, this typically aligns, but oversized or undersized motors may exceed this margin. Variable frequency drive (VFD) circuits present a different challenge: VFD output current contains high-frequency switching harmonics that may cause erratic thermal element response in the GMB63H1PC13. In such applications, electronic trip modules or solid-state breakers with harmonic immunity are often preferred over the thermal-magnetic GMB63H1PC13. Additionally, VFD-driven loads may exhibit conducted EMI that affects the GMB63H1PC13's magnetic mechanism operation. For both HVAC and VFD applications, field testing or manufacturer consultation is advisable before relying solely on the GMB63H1PC13.
  • How does the GMB63H1PC13 integrate with ground fault detection schemes in modern industrial systems, and what upstream protection coordination is necessary? The GMB63H1PC13 is a standard thermal-magnetic breaker without integral ground fault detection (no GFI or GFCI function). In industrial 480V three-phase systems, ground faults are typically detected by upstream ground fault relays or residual current transformers that feed protective relays or electronic trip units on the main breaker. The GMB63H1PC13, as a branch-level device, provides phase-to-phase and phase-to-ground fault protection only through its thermal and magnetic trips. A high-impedance ground fault (such as a partial insulation breakdown with fault current limited by distributed system impedance) may not produce sufficient current to trip the GMB63H1PC13 magnetic element, allowing the fault to persist undetected at the branch level. In such cases, the upstream ground fault detection system must clear the fault by tripping the main breaker or feeder. This coordination implies that the GMB63H1PC13 is not suitable as the sole protection against ground faults; it must be deployed within an architecture that includes independent ground fault detection upstream. For critical loads or applications requiring fast ground fault response, more sophisticated branch-level protection (such as electronic trip breakers with residual current sensing) may be necessary instead of the GMB63H1PC13.
  • What is the expected service life of the GMB63H1PC13 under continuous normal operation, and how do manufacturing year or storage conditions affect breaker reliability? The GMB63H1PC13 has no specified shelf life limit if stored in dry, temperature-controlled conditions (typically 10–40°C, <80% relative humidity). The breaker's service life under continuous normal load is not explicitly limited by the manufacturer; however, the thermal and magnetic trip elements are subject to gradual degradation from thermal cycling and minor contact erosion during normal operation. In practice, industrial-grade breakers like the GMB63H1PC13 typically remain reliable for 10–20 years under normal load conditions, assuming proper ventilation and maintenance. However, if the GMB63H1PC13 is exposed to corrosive environments (salt spray, industrial chemical fumes), the contacts and springs may degrade more rapidly, reducing service life to 5–10 years. Long-term storage of unused GMB63H1PC13 breakers in humid or uncontrolled environments may lead to moisture ingress, causing contact oxidation and reduced conductivity; such breakers should be checked before installation. Additionally, the GMB63H1PC13 manufacturing date affects warranty status and obsolescence risk; very old breakers may have contact materials or arc-quenching designs that no longer meet updated standards, and replacement parts or technical support may be difficult to obtain.
  • Are there pin-compatible or drop-in replacement options for the GMB63H1PC13 if the breaker becomes obsolete or is damaged in service? The GMB63H1PC13 is part of the Carlo Gavazzi GMB63 series, which includes variants with different current ratings (typically 6A, 10A, 13A, 16A, 20A, 25A) and pole configurations. Within the same DIN rail mounting footprint and terminal style, alternative current ratings from the GMB63 series may be physically interchangeable, though electrical coordination will differ. However, drop-in replacements from competing manufacturers (such as ABB, Siemens, Schneider Electric, or Eaton) may have different electrical characteristics, trip curves, or mounting footprints despite similar DIN rail form factors. The GMB63H1PC13 uses standard industrial IEC-compatible terminals, so mechanical mounting is often possible with other IEC 60947-2 compliant devices, but thermal-magnetic coordination will not be preserved unless the replacement device has identical trip characteristics. If the GMB63H1PC13 must be replaced during system operation, careful coordination verification with upstream and downstream protective devices is essential. For critical systems, sourcing an equivalent GMB63 series breaker or consulting the original system designer is recommended before substitution.
  • How do moisture sensitivity, REACH compliance, and ECCN classification of the GMB63H1PC13 affect its use in harsh industrial environments or export scenarios? The GMB63H1PC13 carries a Moisture Sensitivity Level (MSL) designation of "Not Applicable," indicating that the breaker's electronic or semiconductor components do not require moisture-sensitive device handling during storage or installation. This designation simplifies logistics and installation practices compared to MSL-classified components. REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) status indicates the GMB63H1PC13 is "REACH Unaffected," meaning its constituent materials and manufacturing processes do not require REACH compliance registration, which permits unrestricted distribution within the European Union. The ECCN (Export Control Classification Number) designation EAR99 classifies the GMB63H1PC13 as a commodity subject to general U.S. export controls but not requiring specific licensing for most destinations. However, export to embargoed countries or sanctioned end-uses may be restricted; therefore, procurement and logistics personnel should verify that the GMB63H1PC13 destination and application align with applicable export regulations. In harsh industrial environments (chemical plants, offshore installations, mining), the lack of MSL designation means the GMB63H1PC13 can be safely deployed without specialized humidity controls, but the breaker itself remains susceptible to corrosion if installed in corrosive chemical atmospheres; appropriate enclosure ratings and environmental protection are still necessary.
  • What is the interruptible capacity rating of the GMB63H1PC13 at 480V, and how does this limit affect its use in high-fault-current applications such as utility substations or generator-backed systems? While the specific interrupting capacity (Ic) rating at 480V is not detailed in the provided specifications, industrial-grade thermal-magnetic breakers in the 13A class typically have interrupting capacities in the range of 5–25 kA at 480V. The GMB63H1PC13 must operate within its rated interrupting capacity; if the available fault current at the installation point exceeds this limit, the breaker contacts may be damaged, fused, or fail to interrupt cleanly, creating a potential equipment fire or arc flash hazard. In utility substation environments or systems fed by large generators with low source impedance, available fault currents can easily exceed 20 kA at the medium-voltage level; the GMB63H1PC13 would require coordination with current-limiting upstream devices (such as fused disconnects or smaller breakers) to avoid exceeding its Ic rating. Conversely, in distributed systems with long feeder runs or high-impedance sources (such as small generators or solar inverters), the available fault current may be lower, allowing the GMB63H1PC13 to operate safely. System designers must perform a fault study or request available short-circuit current data from the utility or system owner, then verify that the GMB63H1PC13 is rated for the maximum possible fault current at its location, including transient contributions from rotating machinery or battery energy storage systems.
  • *Part No. Manufacturer Target Price(USD) *Request Qty Action
    Add Item

    Enter Your Contact Information

    Submit
    GMB63H1PC13 StockGMB63H1PC13 PriceGMB63H1PC13 Electronics
    GMB63H1PC13 ComponentsGMB63H1PC13 InventoryGMB63H1PC13 Digikey
    Supplier GMB63H1PC13Order GMB63H1PC13 Online Inquiry GMB63H1PC13
    GMB63H1PC13 ImageGMB63H1PC13 PictureGMB63H1PC13 PDF
    GMB63H1PC13 DatasheetDownload GMB63H1PC13 DatasheetManufacturer Carlo Gavazzi
    Related parts for GMB63H1PC13
    Image Part Number Description Manufacturer PDF Get a Quote
    GMB63H1PC10 CIR BRKR THERM-MAG 10A 480/277V Carlo Gavazzi Inc.
    Get a Quote
    GMB633PC50 CIR BRKR THERM-MAG 50A 240VAC Carlo Gavazzi Inc.
    Get a Quote
    GMB63H1PC30 MCB HV UL489 C 1P 30A LUG T Carlo Gavazzi Inc.
    Get a Quote
    GMB63H1PC5 CIR BRKR THERM-MAG 5A 480/277V Carlo Gavazzi Inc.
    Get a Quote
    GMB63H1PC32 MCB HV UL489 C 1P 32A LUG T Carlo Gavazzi Inc.
    Get a Quote
    GMB63H1PC4 CIR BRKR THERM-MAG 4A 480/277V Carlo Gavazzi Inc.
    Get a Quote
    GMB63H1PC2 CIR BRKR THERM-MAG 2A 480/277V Carlo Gavazzi Inc.
    Get a Quote
    GMB633PC60 CIR BRKR THERM-MAG 60A 240VAC Carlo Gavazzi Inc.
    Get a Quote
    GMB63H1PC25 MCB HV UL489 C 1P 25A LUG T Carlo Gavazzi Inc.
    Get a Quote
    GMB633PC6 CIR BRKR THERM-MAG 6A 240VAC Carlo Gavazzi Inc.
    Get a Quote
    GMB63H1PC20 CIR BRKR THERM-MAG 20A 480/277V Carlo Gavazzi Inc.
    Get a Quote
    GMB633PC8 CIR BRKR THERM-MAG 8A 240VAC Carlo Gavazzi Inc.
    Get a Quote
    GMB633PC5 CIR BRKR THERM-MAG 5A 240VAC Carlo Gavazzi
    Get a Quote
    GMB63H1PC1 CIR BRKR THERM-MAG 1A 480/277V Carlo Gavazzi Inc.
    Get a Quote
    GMB63H1PC16 CIR BRKR THERM-MAG 16A 480/277V Carlo Gavazzi Inc.
    Get a Quote
    GMB63H1PC3 CIR BRKR THERM-MAG 3A 480/277V Carlo Gavazzi Inc.
    Get a Quote
    GMB63H1PC0.5 CIR BRKR THERM-MAG 0.5A 480/277V Carlo Gavazzi Inc.
    Get a Quote
    GMB633PC63 CIR BRKR THERM-MAG 63A 240VAC Carlo Gavazzi Inc.
    Get a Quote
    GMB63H1PC15 CIR BRKR THERM-MAG 15A 480/277V Carlo Gavazzi Inc.
    Get a Quote
    GMB63H1PC1.6 CIR BRKR THERM-MAG 1.6A 480/277V Carlo Gavazzi Inc.
    Get a Quote

    News

    More
    Renesas Debuts Flagship RX MCUs on 22 nm Process With Embed...

    Renesas Electronics introduced the RX74M and RX74N, two flagship 32-bit microcontrollers (MCUs) designed for industrial automation and energy infrastr...

    Omnivision Intros Image Sensor Duo Targeting Industrial and...

    Omnivision has expanded its industrial image sensor portfolio with the introduction of two backside-illuminated (BSI) global shutter CMOS sensors, the...

    Google is in talks with Marvell to develop two AI inference...

    On April 19, 2026 (local time), media reports citing sources familiar with the matter revealed that Google, a subsidiary of Alphabet, is in talks with...

    TSMC Advances Panel-Level Packaging Technology; CoPoS Pilot...

    According to *The Business Times*, TSMC’s CoPoS (Chip-on-Panel-on-Substrate) pilot production line began delivering equipment to its R&D team in Febr...

    Anthropic Partners with Google and Broadcom to Deploy Sever...

    On April 6 local time, U.S. artificial intelligence (AI) technology giant Anthropic announced that it has signed a new agreement with Google and Broad...

    New Products

    More
    Texas Instruments TPS92542-Q1 Synchronous Boost Controller

    Texas Instruments TPS92542-Q1 Synchronous Boost Controller contains a synchronous boost controller and a two-channel monolithic synchronous buck LED d...

    Toshiba TB67H453 Single Channel H-Bridge Driver

    Toshiba TB67H453 Single Channel H-Bridge Driver has a current monitoring function with voltage feedback from the ISENSE output pin. The device's absol...

    STMicroelectronics STSAFE-A120 Authentication ICs

    STMicroelectronics STSAFE-A120 Authentication ICs are highly secure integrated circuits designed to protect sensitive data and devices through advance...

    STMicroelectronics STSAFE-A Optimized Authentication ICs

    STMicroelectronics STSAFE-A Optimized Authentication ICs leverage advanced cryptographic algorithms and key management techniques to protect sensitive...

    Diodes Incorporated PI3DPX1235Q 64 Crossbar Linear ReDriver

    Diodes Incorporated PI3DPX1235Q 6:4 Crossbar Linear ReDriver supports DP link-training transparent for source-side applications. The PI3DPX1235Q compl...

    Email: Info@ariat-tech.comHK TEL: +852 30501966ADD: Rm 2703 27F Ho King Comm Center 2-16,
    Fa Yuen St MongKok Kowloon, Hong Kong.